Search PubMed⌕ Search

PubMed · 14580980

Locking Compression Plate.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Christoph Sommer. 2003. Locking Compression Plate.. https://doi.org/10.1016/j.injury.2003.09.019

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Robusticity and osteoarthritis at the trapeziometacarpal joint in a Bronze Age population from Tell Abraq, United Arab Emirates.

Osteoarthritis (OA) is a progressive disease of the joints and can cause pain, reduced range of motion and strength, and ultimately loss of function at affected joints. Osteoarthritis often occurs at sites where biomechanical stress is acutely severe or moderate but habitual over the course of a lifetime. Skeletal remains from an Umm an-Nar tomb at Tell Abraq, United Arab Emirates (ca. 2300 BC), were recovered and represented over 300 individuals of all ages. The remains were disarticulated, commingled, and mostly fragmented. An analysis of 650 well-preserved adult metacarpal and carpal bones, from the tomb's western chamber, revealed that over 53% of the trapeziometacarpal joint facets showed signs of OA varying from mild to severe. The first and second metacarpals and trapezium bones were sided and evaluated for OA at the trapeziometacarpal joint articulations. Osteoarthritis was detected on 53% of the first metacarpals, 40% of the second metacarpals, and 57% of the trapezium bones. All specimens appeared enlarged, and the first metacarpals were assessed for sexual identification and robusticity. Eighty-five percent of the bones were probable males, and more than 80% of them had a robusticity index of 60 or higher. A strong correlation was found between OA, sex, and robusticity. High levels of OA and robusticity at the thumb suggest that the people of Tell Abraq were habitually involved in biomechanically challenging work with their hands.

Biomechanical Phenomena↗

Paleopathological study of hallux valgus.

Hallux valgus is the abnormal lateral deviation of the great toe. The principal cause is biomechanical, specifically the habitual use of footwear which constricts the toes. In this study, descriptions of the anatomical changes of hallux valgus from published cadaveric and clinical studies were used to generate criteria for identifying the condition in ancient skeletal remains. The value of systematic scoring of hallux valgus in paleopathology is illustrated using two British skeletal series, one dating from the earlier and one from the later Medieval period. It was found that hallux valgus was restricted to later Medieval burials. This appears consistent with archaeological and historical evidence for a rise in popularity, during the late Medieval period (at least among the richer social classes), of narrow, pointed shoes which would have constricted the toes.

Biomechanical Phenomena↗

Biomechanical assessment of lateral stiffness elements in the suspension system of a backpack.

The purpose of this study was to examine the change in load distribution characteristics associated with adding lateral stiffness elements (rods) to a rucksack (backpack). A load distribution mannequin was instrumented with two 3D load cells to allow determination of the load applied to the shoulders and upper torso independent of the load applied to the hips and lower trunk. Position and mass of the payload (25 kg) were fixed at the centre of the volume of the rucksack and held constant during all testing. It was hypothesized that lateral rods would provide a force bridge that transfers part of the vertical load of the pack from the upper back and shoulders to the hip belt thereby reducing the vertical load on the torso, and possibly reducing the horizontal reaction force that produces a shear load on the spine. Results showed that these active stiffness elements shifted 14% of the vertical load from the upper torso to the pelvic region with lumbar shear load remaining relatively unchanged for all combinations of shoulder strap and waist belt tension. The lateral rods also provided a mean increase of 12% in the extensor moment at the L3-L4 level, thus reducing some demand on the erector spinae muscles.

Biomechanical Phenomena↗