Search PubMed⌕ Search

PubMed · 1450429

Bone marrow cell differential counts obtained by multidimensional flow cytometry.

Abstract

Five-dimensional flow cytometric analysis of normal bone marrow aspirates was utilized to determine the frequency of neutrophils, eosinophils, monocytes, lymphocytes, nucleated erythrocytes, reticulocytes, platelets, and a cell population that included blasts of each of the cell lineages, megakaryocytes, plasma cells, and basophils. Each of these bone marrow cell populations had unique features with respect to forward light scatter, orthogonal light scatter, and staining with Thiazole-Orange, LDS-751, and CD45 labeled with Phycoerythrin (PE). The identity of the cell populations was verified by sorting each of the cell populations and subsequent light microscopic examination of the cells. The frequencies of the nucleated bone marrow cell subpopulations of 50 normal donors were for neutrophils, mean 72.3%; SD +/- 5.1; 95% limits, 70.9-73.8%; eosinophils, mean 1.8%; SD +/- 1.3; 95% limits, 1.4-2.1%; monocytes, mean, 2.8%; SD +/- 1.2; 95% limits, 2.5-3.1%; lymphocytes, mean 12.1%; SD +/- 3.6; 95% limits 11.1-13.2%; nucleated erythrocytes, mean 8.9%; SD +/- 3.9; 95% limits, 7.8-10.1%; and the cell population that included blasts of each of the cell lineages, megakaryocytes, plasma cells, and basophils, mean 1.6%; SD +/- 1.2; 95% limits, 1.3-1.9%. The percentage of reticulocytes in bone marrow aspirates from 50 normal donors correlated with the reticulocyte frequency in the peripheral blood of these donors. However, the mean frequency of reticulocytes was significantly greater (p < 0.0001) in bone marrow (mean 2.19%; SD +/- 0.88) than in peripheral blood (mean 1.71%; SD +/- 0.88). The technique could discriminate between immature and mature reticulocytes based on the brighter staining with both Thiazole-Orange and LDS-751 of the immature reticulocytes. This was confirmed by cell sorting of both reticulocyte populations, which revealed larger clumps of New Methylene Blue staining material in the brighter Thiazole-Orange and LDS-751 stained reticulocytes. The immature reticulocytes were present in normal bone marrow, but not in normal peripheral blood. As expected, a significantly greater frequency of nucleated cells was found in bone marrow aspirates (mean 0.85%; SD +/- 0.59) than in peripheral blood (mean 0.20%; SD +/- 0.11). The frequency of platelets was significantly lower in bone marrow (mean 1.24%; SD +/- 0.69) than in peripheral blood (mean 2.94%, SD +/- 1.14). Flow cytometric bone marrow analysis can provide clinical laboratories with a technique that generates quantitative bone marrow cell differentials and potentially can reduce the need for light microscopic examination of bone marrow smears.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L W Terstappen, J Levin. 1992. Bone marrow cell differential counts obtained by multidimensional flow cytometry.. https://pubmed.ncbi.nlm.nih.gov/1450429/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Design, synthesis and biological evaluation of hydroxybenzothiazole-linked benzothiazole/benzoxazole conjugates as potent dual &#x3b1;-amylase and &#x3b1;-glucosidase inhibitors.

The current study focuses on the synthesis and evaluation of novel Hydroxybenzothiazole-Linked Benzothiazole/Benzoxazole Conjugates to target Diabetes Mellitus (DM) by inhibiting &#x3b1;-amylase and &#x3b1;-glucosidase. Spectroscopic methods, including 1H and 13C NMR spectroscopy, were employed to confirm the structures of newly synthesized conjugates. The findings of in-vitro analysis displayed that the synthesized derivatives inhibited &#x3b1;-amylase and &#x3b1;-glucosidase enzymes with IC50 values ranging from 3.65&#xa0;&#xb1;&#xa0;0.20&#xa0;&#x3bc;M to 32.15&#xa0;&#xb1;&#xa0;3.20&#xa0;&#x3bc;M on &#x3b1;-amylase and 5.92&#xa0;&#xb1;&#xa0;0.80&#xa0;&#x3bc;M to 35.60&#xa0;&#xb1;&#xa0;3.40&#xa0;&#x3bc;M on &#x3b1;-glucosidase, in contrast to the reference drug Acarbose (&#x3b1;-amylase IC50&#xa0;=&#xa0;8.25&#xa0;&#xb1;&#xa0;0.80&#xa0;&#x3bc;M; &#x3b1;-glucosidase IC50&#xa0;=&#xa0;10.75&#xa0;&#xb1;&#xa0;1.10&#xa0;&#x3bc;M). Among the series 9a-9f and 10a-10f, analogs 10&#xa0;f, 10b, 9b, and 9e displayed superior anti-diabetic activity compared to the reference drug Acarbose. The inhibitory activity of these conjugates can be attributed to their favorable and stable interactions with critical amino acid residues of targeted enzymes, as revealed through molecular docking analysis. ADMET predictions and drug-likeness evaluations showed favorable pharmacokinetic features, while DFT investigations revealed electronic insights related to bioactivity. Experimental outcomes and in silico support display that these potent Hydroxybenzothiazole-Linked Benzothiazole/Benzoxazole Conjugates were comparable to an existing diabetic mellitus inhibitor while conserving an acceptable safety profile, specifying potential for further therapeutic development and optimization against diabetic Mellitus.

Benzothiazoles↗

Valvular heart disease in Parkinson's disease patients treated with dopamine agonists: a reader-blinded monocenter echocardiography study.

Fibrotic valvular heart disease (VHD) has been reported in association with ergot dopamine agonists (DAs), but the current database is insufficient regarding clinical relevance and comparison to data on non-ergot DAs. We evaluated the effects of four DAs (pergolide, cabergoline, ropinirole, pramipexole) on morphology and function of heart valves in patients with Parkinson's disease (PD) to determine the frequency and clinical relevance of DA-induced VHD. A total of 85 patients treated with ergot or non-ergot DAs and 38 age-matched controls were evaluated by transthoracic echocardiography. Valvular pathology was assessed by established criteria of valvular regurgitation and a VHD scoring system. Both grading systems revealed increased frequency of VHD in ergot DA patients compared to both non-ergot DA patients and controls with 22% of ergot DA patients having moderate VHD versus 3% of non-ergot DA patients and none of controls (P = 0.001). We did not find correlations of echocardiographic findings with duration/cumulative dose of treatment, age, or vascular risk factors. Our data suggest that ergot DAs are associated with higher prevalence of VHD compared to non-ergot DAs and controls. Standard echocardiography seems sufficient to detect VHD in PD patients treated with DAs.

Benzothiazoles↗

Detection and quantification of hepatitis B virus DNA by SYBR green real-time polymerase chain reaction.

A single-round real-time polymerase chain reaction (PCR) assay based on SYBR green dye technology for the detection and quantification of hepatitis B virus (HBV) DNA in serum was evaluated and compared with a qualitative nested PCR and the Cobas Amplicor HBV Monitor assay (Roche Molecular Diagnostics, Milan, Italy). The performance of the real-time PCR assay was evaluated in a routine clinical laboratory setting with a total of 212 clinical specimens. The sensitivity of the real-time PCR corresponded to 31 IU/ml (70 copies/ml), and comparison with the qualitative nested PCR showed significant concordance for 94% of samples. The linear curve over 7 log units, spanning 10(3)-10(9) IU/ml (2.28 x 10(3) to 2.28 x 10(9) copies/ml), was observed in the quantitative determination. The interexperimental variability coefficient of the assay ranged from 0.22 to 0.39 and the intraexperimental variability coefficient from 0.24 to 0.41. By excluding values outside of the dynamic ranges of both tests, the HBV Monitor and the real-time PCR gave an agreement within +/-1 log unit for 90% of samples, while those for the remaining 10% were found to be above 1 log unit but less than 1.5 log units. When the results inside and outside the dynamic range of the HBV Monitor were examined, 90% of the results were in agreement. In conclusion, the real-time PCR based on SYBR green technology proved suitable for routine diagnostic purposes, showing good sensitivity, high specificity, high reproducibility, and good linearity over a broad dynamic range of quantification.

Benzothiazoles↗