Search PubMed⌕ Search

PubMed · 14354282

Some experiments with electrophoretic patch tests.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H HAXTHAUSEN. 1955. Some experiments with electrophoretic patch tests.. https://doi.org/10.1038/jid.1955.34

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

3-D transient electrophoretic motion of a spherical particle in a T-shaped rectangular microchannel.

This paper considers the electrophoretic motion of a spherical particle in an aqueous electrolyte solution in a T-shaped rectangular microchannel, where the size of the channel is close to that of the particle. This is a complicated transient process where the electric field, the flow field, and the particle motion are coupled together. A theoretical model was developed to investigate the influences of the applied electric potentials, the zeta potentials of the channel and the particle, and the size of the particle on the particle motion. A direct numerical simulation method using the finite element method is employed. This method employs a generalized Galerkin finite element formulation that incorporates both equations of the fluid flow and equations of the particle motion into a single variational equation where the hydrodynamic interactions are eliminated. The ALE method is used to track the surface of the particle at each time step. The numerical results show that the electric field in the T-shaped microchannel is influenced by the presence of the particle, and that the particle motion is influenced by the applied electric potentials and the zeta potentials of the channel and the particle. The path of the particle motion is dominated by the local electric field and the ratio of the zeta potential of the channel to that of the particle. The particle's velocity is also dependent on its size in a small channel.

Electrophoresis↗

Assay of phenolic compounds in red wine by on-line combination of capillary isotachophoresis with capillary zone electrophoresis.

The on-line combination of capillary zone electrophoresis (CZE) with capillary isotachophoresis (ITP) increases significantly the separation capability and sensitivity of capillary electrophoresis. This technique was used for separation and quantification of fourteen selected natural constituents in red wine belonging to flavonoids and phenolic acids. The leading electrolyte (LE) in the ITP pre-separation step was 10 mM HCl of pH* 7.2 with Tris as counterion, the terminating electrolyte (TE) was 50 mM boric acid of pH* 8.2 (adjusted with barium hydroxide). The background electrolyte in the electrophoretic step contained 25 mM beta-hydroxy-4-morpholinopropanesulfonic acid (MOPSO), 50 mM Tris, 15 mM boric acid and 5 mM beta-cyclodextrin of pH* 8.5. The content of methanol in all electrolytes was 20% (v/v). For exact timing of the transfer of isotachophoretically stacked analyte zones into the CZE column and for the control of the residual amount of leading and terminating ITP electrolytes picric acid was used as coloured marker. The R.S.D. values (n = 6) ranged between approximately 0.1% (for 0.25 microg ml(-1) rutin) and approximately 11% (for 0.25 microg ml(-1) of quercitrin). Detection limits were 30 ng mi(-1) for phenolic acids, quercitrin and rutin, 100 ng ml(-1) for quercetin, kaempferol and epicatechin and 250 ng ml(-1) for catechin. A single analysis took 45 min.

Electrophoresis↗

Parametric investigation on the effect of channel topologies on electrophoretic separations.

This paper presents a systematic study that illustrates the importance of the topologies of microchannels on electrokinetically based separation. Using theoretical and numerical analyses, we designed and showed that topologies that significantly increased the surface-to-volume ratio of the channel can provide dramatic improvement in the ability of the channel both to dissipate the heat generated by Joule heating and to reduce the axial dispersion associated with the siphoning effect. The incremental benefit and tradeoff of geometric complexity was also evaluated. The improvement offered by topographically patterned channels, such as finned structures, is especially pertinent in the development of preparative or semi-preparative scale electrokinetically driven separations, such as capillary electrophoresis and capillary electrochromatography, in which large cross sections of channels are required to achieve the needed volumetric throughput.

Electrophoresis↗