Search PubMed⌕ Search

PubMed · 14320339

[THIN-LAYER CHROMATOGRAPHY].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W KINZE. 1964. [THIN-LAYER CHROMATOGRAPHY].. https://pubmed.ncbi.nlm.nih.gov/14320339/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Building the stator of the yeast vacuolar-ATPase: specific interaction between subunits E and G.

The vacuolar (H+)-ATPase (or V-ATPase) is a membrane protein complex that is structurally related to F1 and F0 ATP synthases. The V-ATPase is composed of an integral domain (V0) and a peripheral domain (V1) connected by a central stalk and up to three peripheral stalks. The number of peripheral stalks and the proteins that comprise them remain controversial. We have expressed subunits E and G in Escherichia coli as maltose binding protein fusion proteins and detected a specific interaction between these two subunits. This interaction was specific for subunits E and G and was confirmed by co-expression of the subunits from a bicistronic vector. The EG complex was characterized using size exclusion chromatography, cross-linking with short length chemical cross-linkers, circular dichroism spectroscopy, and electron microscopy. The results indicate a tight interaction between subunits E and G and revealed interacting helices in the EG complex with a length of about 220 angstroms. We propose that the V-ATPase EG complex forms one of the peripheral stators similar to the one formed by the two copies of subunit b in F-ATPase.

Chromatography↗

Chromatographic preconcentration coupled to capillary electrophoresis via an in-line injection valve.

A preconcentration-capillary electrophoresis (CE) system using a small precolumn in combination with an in-line injection valve is presented. The advantage of the present design is the ability to perform the sample preconcentration fully independently from the CE separation and to prevent sample matrix and washing solvents from entering the CE capillary. With a micro injection valve, sample could be effectively introduced into the CE system in an in-line fashion without seriously affecting the CE separation efficiency. Breakthrough volume, desorption efficiency, and elution volume for the C18 microcolumn (5 x 0.5 mm i.d.) were established, yielding values of 750 microL, 70%, and 0.9-1.1 microL, respectively, using enkephalin peptides. The time between the start of the desorption of the analytes from the precolumn and the injection into the CE system was also studied in order to achieve optimal sensitivity and separation efficiency. The performance of the complete system was demonstrated by the preconcentration and separation of an enkephalin mixture. Using a sample volume of 250 microL and a CE injection voltage of -15 kV for 12 s, linearity was observed over 2 orders of magnitude, and detection limits (S/N = 3) were in the 5-10 ng/mL range. A 1000-fold sensitivity enhancement is obtained using this setup, as compared to a regular CE setup. For 100 ng/mL samples, repeatabilities (RSDs) of migration time and peak area were 1.2 and 11%, respectively.

Chromatography↗