Search PubMed⌕ Search

PubMed · 14267917

A SIMPLE ELECTRONIC INTERVALOMETER.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J A SIRS, C STOLINSKI. 1965. A SIMPLE ELECTRONIC INTERVALOMETER.. https://pubmed.ncbi.nlm.nih.gov/14267917/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Pyrolysis study of halogen-containing aromatics reflecting reactions with polypropylene in a posttreatment decontamination process.

Halogen-containing aromatics, mainly bromine-containing phenols, are harmful compounds contaminating pyrolysis oil from electronic boards containing halogenated flame retardants. In addition,theirformation increases the potential for evolution of polybrominated dibenzo-p-dioxins (PBDDs) and dibenzofurans (PBDFs) at relatively low temperature (up to 500 degrees C). As a model compound, 2,4-dibromophenol (DBP) was pyrolyzed at 290-450 degrees C. While its pyrolysis in a nitrogen flow reactor or in encapsulated ampules yields bromine-containing phenols, phenoxyphenols, PBDDs, and PBDFs, pyrolysis of DBP in a hydrogen-donating medium of polypropylene (PP) at 290-350 degrees C mainly results in the formation of phenol and HBr, indicating the occurrence of a facile hydrodebromination of DBP. The hydrodebromination efficiency depends on temperature, pressure, and the ratio of the initial components. This thermal behavior of DBP is compared to that of 2,4-dichlorophenol and decabromodiphenyl ether. A treatment of halogen-containing aromatics with PP offers a new perspective on the development of low-environmental-impact disposal processes for electronic scrap.

Electronics↗

Scanning tunneling microscopy experiments on single molecular landers.

Molecular landers are molecules comprising of a central rigid molecular wire maintained above a metallic surface by organic spacers, which allows specific ultrahigh vacuum-scanning tunneling microscopy experiments to be performed at the single-molecule level. The understanding of the molecule-surface interactions, intramolecular mechanics, and the possibility to perform extremely precise tip-induced manipulation permit these molecules to be brought in contact with a nanoelectrode and the resulting electronic interaction to be analyzed in well controlled conditions.

Electronics↗

Digital position determination system for electron microscopy.

The precise determination of object positions within a specimen grid is important for many applications in electron microscopy. For example, real-time position determination is necessary for current statistical approaches and the efficient mapping and relocation of objects. Unfortunately, precise real-time position determination is not available on many older electron microscopes with manual stage controls. This report demonstrates the cost-effective and flexible implementation of a digital position determination system that can be adapted to many hand-operated electron microscopes. A customized solution that includes the hardware and software to accomplish position determination is presented. Lists of required parts, instructions for building the hardware, and descriptions of the developed programs are included. Two LED-photodiode assemblies detect x and y movements via an optical wheel that is in physical contact with the mechanical x and y stage control elements. These detector assemblies are interfaced with an integrated circuit that converts movement information into serial port-compatible signals, which are interpreted by a computer with specialized software. Two electron microscopes, a Philips CM12 (S)TEM and a Philips 201 TEM, were equipped with the described digital position determination system. The position fidelity and position fidelity after reloading of grids were determined for both microscopes. The determined position deviation was 1.06 microm in the x axis and 0.565 microm in the y axis for the Philips CM12 (S)TEM, and 0.303 microm in the x axis and 0.545 microm in the y axis for the Philips 201 TEM. After reloading and computational realigning, the determined average position variation was 2.66 microm in the x axis and 2.61 microm in the y axis for the Philips CM12 (S)TEM, and 1.13 microm in the x axis and 1.27 microm in the y axis for the Philips 201 TEM.

Electronics↗