Search PubMed⌕ Search

PubMed · 14261493

[DENTIN SENSITIVITY].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M BRAENNSTROEM. 1965. [DENTIN SENSITIVITY].. https://pubmed.ncbi.nlm.nih.gov/14261493/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effects of tubule orientation on fatigue crack growth in dentin.

The fracture of restored teeth is a significant obstacle to lifelong oral health. Recent studies suggest that fatigue cracks originate at flaws introduced during cavity preparation and that fatigue crack growth is a principle cause of restored tooth fractures. In this study, the rate of fatigue crack growth in bovine dentin was estimated under mode I cyclic loading. Double cantilever beam (DCB) specimens were obtained from bovine molars and subjected to high cycle fatigue loading (10(5) < N < 10(6)). The fatigue crack growth rates were measured and used to estimate the crack growth exponent and coefficient according to the Paris Law. The average fatigue crack growth exponent was 4.7 +/- 0.6 for crack growth parallel to the dentin tubules, which was significantly larger than 4.3 +/- 0.5 for crack growth perpendicular to the tubules (t-test, CI > 80%). Although the crack growth rates varied considerably, there was no significant dependence on tubule orientation or tubule density. However, specific features of the fracture surfaces and tendencies for crack curving away from the tubules suggested preferential fatigue crack growth perpendicular to the dentin tubules. Results from this study are being used to guide an experimental investigation of fatigue crack growth in human dentin.

Dentin↗

Microhardness of superficial and deep sound human dentin.

Our purpose in this study was to determine the microhardness of superficial and deep dentin by means of two indentation methods (Knoop and Vickers) under two different applied loads. Twelve dentin discs approximately 2-mm thick were obtained from both superficial and deep dentin by transversally sectioning the crowns of sound, extracted human third molars with a diamond blade under water irrigation. Dentin surfaces were sequentially polished, and indentations (n = 20 per surface) were performed with either Vickers indentor at loads of 300 and 500 g, respectively, or Knoop indentor at loads of 50 and 100 g, respectively. Average Vickers hardness number (VHN) and Knoop hardness number (KHN) were calculated and treated with two-way analysis of variance (ANOVA) and Student's t test. Microhardness of dentin was not influenced by the different loads applied for both indentation methods. Knoop hardness was significantly higher for superficial than for deep dentin (p < 0.05). Conversely, Vickers hardness was not significantly different for both substrates (p > 0.05). Differences in dentin hardness as a function of depth exist, but they might not be relevant, and no alteration of the distribution of stresses along the adhesive interface is expected.

Dentin↗

Fracture toughness of human dentin.

The purpose of this study was to determine the fracture toughness (K(IC)) of human dentin and to test the null hypothesis that K(IC) is not affected by the orientation of dentinal tubules relative to the plane of crack propagation. Triangular prisms (4 x 4 x 4 x 8 mm) were obtained from human molars and tested using the notchless triangular prism (NTP) specimen K(IC) test. Dentin prisms were prepared so that the plane of crack propagation would have three different orientations relative to the orientation of dentinal tubules: perpendicular (PE), parallel aligned (PAA), and parallel transverse (PAT). The prepared specimens were secured in the specimen holder and loaded in tension until fracture or crack arrest. The maximum load recorded was used to calculate K(IC). There was no significant difference between the K(IC) of PAA specimens (1.97 +/- 0.17 MPa/m(1/2)) and PAT (2.02 +/- 0.18 MPa/m(1/2)). The K(IC) for the PE specimens (1.13 +/- 0.36 MPa/m(1/2)) was significantly lower. The SEM images of the fractured surfaces showed distinct differences that were correlated with the determined K(IC) values. The fractured surfaces of PAA and PAT specimens were rougher compared to PE specimens. Both the hyper mineralized peritubular dentin and the orientation of collagen fibrils surrounding the tubules could be responsible for the significant differences in K(IC). The results of this study identified a significant anisotropy of dentin with respect to its K(IC).

Dentin↗