Lead extraction. Indications and techniques.

Abstract

Each of the extraction techniques and their ancillary tools was reported as used successfully; however, until now, no technique has been successful when used in more than a few isolated instances. The technique for intravascular countertraction and the associated tools described in this paper were devised and selected in an attempt to develop one technique to be used on all patients, with all types of leads, and with a very low complication rate. Its versatility permitted single or multiple lead extractions combined with the precision of selecting and extracting a specific lead. In our experience, as well as the experience of others, the techniques described in this paper have proved to be superior by minimizing the inherent risk and morbidity, allowing us to expand the indications for lead removal beyond septicemia and free-floating leads, to include infection, abandonment of pockets, and replacement of malfunctioning or fractured leads. Intravascular countertraction was a consistently safe and efficacious method of removing transvenous pacemaker leads regardless of the duration of the implant, thus permitting extractions in patients not considered candidates for a more extensive surgical procedure. Intravascular countertraction encompasses surgical and fluoroscopic techniques possessed by most physicians experienced in pacemaker and automatic implantable cardioverter defibrillator implants. However, there is a learning curve, predicating caution for the inexperienced physician. In addition, advanced surgical skills may be needed in handling associated conditions such as debridement and primary closure of chronically inflamed tissues, especially in submuscular pockets and sinus tracts in the neck. Although the potential for a cardiovascular complication is small, it does exist, and cardiovascular surgical backup is a recommended precaution.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C L Byrd, S J Schwartz, N Hedin. 1992. Lead extraction. Indications and techniques.. https://searchpubmed.org/record/pubmed%3A1423384/lead-extraction-indications-and-techniques

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search PubMed by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

Invited commentary.

Explore the source record for details and available documents.

Cardiopulmonary Bypass↗

Continuous SvO2 measurement in infants undergoing congenital heart surgery--first clinical experiences with a new fiberoptic probe.

BACKGROUND: SvO2-guided therapy, using fiberoptic oximetric catheters can help to improve the outcome after complex congenital heart surgery especially in infants undergoing the Stage 1-Norwood-Procedure. So far, fiberoptic catheters have to be placed transthoracically by the surgeon into the vena cava or the pulmonary artery putting the infant at an additional risk of bleeding at the time of catheter removal. METHODS: We used a new percutaneously applicable fiberoptic probe for continuous monitoring of central venous saturation in three infants undergoing modifications of the Stage 1-Norwood-Procedure (reconstruction of the aortic arch), two in combination with a bidirectional cavopulmonary connection (Glenn shunt), the third with reconstruction of the pulmonary arteries (biventricular repair). The approved clinical monitoring system consisted of a small (2 F) fiberoptic probe and a bed-side-monitor. The probe was inserted via the routine central venous access for such a case. RESULTS: Continuous SvO2 measurement is feasible in infants using the CeVOX system in combination with routine central venous access, and the advantages of continuous monitoring are discussed. CONCLUSIONS: We believe that compared with transthoracically inserted oximetric catheter, the presented percutaneous technique avoids additional risks at the time of catheter removal (i.e. bleeding) and has become part of our standard management.

Cardiopulmonary Bypass↗

An alternative pathway for fibrinolysis is activated in patients who have undergone cardiopulmonary bypass surgery and major abdominal surgery.

INTRODUCTION: We conducted this prospective study in order to investigate the hypotheses that an alternative pathway for fibrinolysis is activated in patients who have undergone cardiopulmonary bypass (CPB) surgery and major abdominal surgery and that the levels of fibrin degradation products digested by polymorphonuclear neutrophil elastase (elastase-XDP) and the D-dimer increase in the patients' plasma. MATERIALS AND METHODS: We studied a total of 77 patients who were scheduled to undergo either CPB surgery (36 patients) or major abdominal surgery (41 patients) and then measured the elastase-XDP and D-dimer levels at several time points both during and after the surgeries. The CPB surgery was divided into surgery for aortic dissection (AD) and cardiac surgery. The major abdominal surgery consists of hepatic resection and esophagectomy. RESULTS: The elastase-XDP and D-dimer levels significantly increased in the patients who underwent both CPB surgery and major abdominal surgery. The elastase-XDP levels in AD surgery showed highest values at the end of the CPB, while the levels in the other surgeries reached their peak on the day after the surgery. Statistical difference was seen in the levels of elastase-XDP among the three subgroups undergoing a hepatic resection. While we found significant correlations between the levels of elastase-XDP and D-dimer in patients undergoing CPB surgery and a subsegmentectomy of a cirrhotic liver, the correlation coefficients were markedly low in comparison to those of the other surgeries. CONCLUSIONS: Our findings demonstrated that the elastase-mediated pathway of fibrinolysis is activated to varying degrees depending on the surgery performed. Variations in the correlation coefficients between the levels of elastase-XDP and D-dimer may suggest that elastase-mediated fibrinolysis play a different role from the physiological fibrinolysis mediated by plasmin.

Cardiopulmonary Bypass↗