A RAPID MICRO METHOD FOR RECORDING RED CELL OSMOTIC FRAGILITY BY CONTINUOUS DECREASE OF SALT CONCENTRATION.

Abstract

A single volume of 0.075 ml. of a 1 in 10 dilution of whole blood in isotonic NaCl solution is introduced into a container cell, two walls of which are made of a dialysing membrane. The container cell is introduced into a test tube of distilled water, placed in an instrument which is essentially a colorimeter with a recorder, between the source of light and the photoelectric cell. Dialysis through the membrane results in a continuous decrease in the salt concentration of the medium surrounding the erythrocytes. The measurement of the degree of haemolysis is based on the increasing transparency of the erythrocyte suspension while haemolysis takes place. Recording this increasing light transmission as a function of time, i.e., as a function of decreasing salt concentration, yields the osmotic fragility curve. The automatically recorded curve is obtained in less than 10 minutes.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D DANON. 1963. A RAPID MICRO METHOD FOR RECORDING RED CELL OSMOTIC FRAGILITY BY CONTINUOUS DECREASE OF SALT CONCENTRATION.. https://doi.org/10.1136/jcp.16.4.377

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Routine transfusion of Rh(D)-positive RBCs to Rh(D)-negative patients designated as do not resuscitate conserves Rh(D)-negative red blood cell inventory.

BACKGROUND: A minority of blood donors are Rh(D)-negative, and Rh(D)-negative red blood cell (RBC) products are often overutilized. As such, Rh(D)-negative RBCs may be difficult to maintain in blood bank inventory. STUDY DESIGN AND METHODS: We changed our blood bank laboratory policy to approve non-alloimmunized Rh(D)-negative patients to receive Rh(D)-positive RBCs for routine transfusion under defined criteria. Those criteria included Rh(D)-negative males (all ages) and females (aged >50 years) who were designated as do not resuscitate (DNR), either with or without intubation, in the electronic medical record. RESULTS: From August 15, 2024 through August 15, 2025, a total of 204 Rh(D)-negative patients met the above criteria and were approved to receive routine Rh(D)-positive RBC transfusions. Within that group, 23 patients received Rh(D)-positive RBCs. The remaining patients either did not require transfusion or were issued Rh(D)-negative RBC units. Since implementing this practice, a total of 68 Rh(D)-negative units were conserved during this time frame. Notably, 28 of the 68 units (41%) were type O, Rh(D)-negative. DISCUSSION: Rh(D)-positive RBCs can be routinely given to non-alloimmunized Rh(D)-negative patients who are not at risk for developing hemolytic disease of the fetus and newborn (HDFN). By creating clear guidelines for the routine administration of Rh(D)-positive RBCs to patients who are not at risk for HDFN, the inventory of Rh(D)-negative RBC units can be directed to those patients who would most benefit from this limited resource.

Erythrocytes↗

Development of a novel compact sonicator for cell disruption.

Ultrasound microbial cell disrupters operating at around 20 kHz are often physically large and, due to significant heating, can be unsuitable for small sample volumes where biochemical integrity of the extracted product is required. Development of a compact device based on a 63.5-mm diameter, 6.5-mm thick tubular transducer for rapid cell disruption in small-volume samples in a high-intensity acoustic cavitation field with minimal temperature rises is described here. Suspensions of Saccharomyces cerevisiae were exposed to cavitation for various times in the compact device and a 20-kHz probe sonicator. Cell disruption was assessed by protein release and by staining. Yeast cell disruption was greater in the novel 267-kHz sonicator than in the 20-kHz probe sonicator for the same exposure time. A 1-dimensional (1-D) transfer matrix model analysis for piezoelectric resonators was applied to an axial cross-section of the tubular sonicator to predict frequencies of mechanical resonance in the sample volume associated with maximum acoustic pressure. Admittance measurements identified frequencies of electrical resonance. Ultrasonic cavitation noise peaks were detected by a hydrophone at both the mechanical and electrical resonances. Cell breakage efficiency was twice as great in terms of protein released per dissipated watt at the mechanical resonance predicted by the model, compared to those at the electrical resonance frequencies. The results form a basis for rational design of an ultrasound cell disruption technique for small-volume samples.

Erythrocytes↗