Search PubMed⌕ Search

PubMed · 13726501

Electron microscopy.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S G ELLIS. 1961-02-01. Electron microscopy.. https://pubmed.ncbi.nlm.nih.gov/13726501/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Technical note: reconstructing dose distributions from manually planned electron boosts in breast radiotherapy.

PURPOSE: In breast radiotherapy, delivery of manually-calculated electron boosts limits retrospective dose-response analyses as dose distribution is unavailable. This work evaluates the feasibility of reconstructing dose distributions from manually planned electron boosts in breast-conserving radiotherapy. METHODS: Only 72 out of 198 breast cancer patients had complete stored dose distributions from sequential electron boosts in the REQUITE study. Arbitrary data from 70/72 patients were used to develop and validate dose reconstruction method. Twenty patients were used to determine optimal parameters for Monte-Carlo-based (MC) electron dose reconstruction on RayStation (v.11B-R), considering CT-calibration curve, MC-history number, andcalculation grid resolution. Remaining 50 patients were used to quantify dose reconstruction accuracy. The similarity between reconstructed and stored dose was evaluated using 3D-gamma index and dosimetric parameters extracted from breast and tumour bed contours. Dose difference location was evaluated using dose-location histogram. RESULTS: Calculation grid resolution significantly impacted electron dose distribution (p&#xa0;<&#xa0;0.01), where the finest grid (0.15&#xa0;cm) showed highest similarity to stored doses. CT-calibration curve and MC-history number had a negligible influence on dose reconstruction. Dosimetric difference between reconstructed and stored doses was&#xa0;<&#xa0;1&#xa0;Gy for breast and tumour bed. Reconstructed dose was achieved&#xa0;>&#xa0;90% gamma passing rate in the validation set. However, around 2.5&#xa0;Gy dose differences were observed at the skin and tissue interface regions. CONCLUSIONS: Retrospective electron boost dose reconstruction is feasible with acceptable accuracy, and could increase data completeness in large cohort studies. Caution is advised when assessing dose near tissue interface and further validation is needed outside the REQUITE dataset.

Electrons↗

Electronic transitions of the Soret band of reaction centers from Rhodobacter sphaeroides studied by femtosecond transient absorbance spectroscopy.

The Soret band of reaction centers from Rhodobacter sphaeroides has been systematically studied using femtosecond transient absorption spectroscopy. When the excitation wavelength was scanned over the entire Soret band, the approximate absorption spectra of the bacteriochlorophyll dimer, the monomer bacteriochlorophylls, and the bacteriopheophytins within the Soret band were determined by analyzing the ground state bleaching with about 100 fs resolution. The main contribution of H is on the blue end of the spectrum, peaking near 350 nm, P absorbs mostly on the red side of the spectrum, but probably has multiple bands, and the main absorbance of B likely lies between H and P, overlapping with P on the red side (particularly near 390 nm). The energy transfer from B to P in the QY band takes about 300 fs when Soret-band excitation is used and the time constant of overall energy transfer from H to B to P in the QY band when H is specifically excited near 350 nm is about 500 fs. Internal conversion after Soret-band excitation is the rate-limiting step for the energy-transfer process. The time constant of internal conversion for B and P is less than 300 fs, and for H it is about 500 fs.

Electrons↗

Evidence for many resolvable structures within conformation types of electrosprayed ubiquitin ions.

A new two-dimensional ion mobility spectrometry approach combined with mass spectrometry has been used to examine ubiquitin ions in the gas phase. In this approach ions are separated in an initial drift tube into conformation types (defined by their collision cross sections) and then a gate is used to introduce a narrow distribution of mobility-separated ions into a second drift tube for subsequent separation. The results show that upon selection a narrow peak shape is retained through the second drift tube. This requires that at 300 K the selected distribution does not interconvert substantially within the broader range of structures associated with the conformation type within the approximately 10-20 ms time scale of these experiments. For the [M + 7H]7+ ion, it appears that many ( approximately 5-10) narrow selections can be made across each of the compact, partially-folded, and elongated conformer types, defined previously (Int. J. Mass Spectrom. 1999, 187, 37-47).

Electrons↗