Search PubMedSearch

PubMed · 1369350

Biosensors for process control.

Abstract

Biosensors have been extensively studied during the last 20 years, and a myriad of laboratory biosensors have been developed. Improvements are required in biosensor design and performance before they become widely accepted in industrial process monitoring. However, as the biotechnology industry expands, biosensors may become more acceptable because, despite their limitations, they are the only devices capable of delivering the information required.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S L Brooks, I J Higgins, J D Newman, A P Turner. 1991. Biosensors for process control.. https://doi.org/10.1016/0141-0229(91)90115-q

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

From host response to genomic targets: electrochemical biosensing of tuberculosis biomarkers.

Tuberculosis (TB) remains one of the leading causes of death from a single infectious agent worldwide, with timely diagnosis continuing to be a major challenge, particularly in resource-limited settings. Conventional TB diagnostic methods are limited by low sensitivity, long turnaround times, and an inability to reliably differentiate latent from active disease. Biomarker-based diagnostic strategies have therefore gained increasing attention as they offer the potential to improve early detection, disease differentiation, and treatment monitoring. Herein, we examine electrochemical biosensing strategies for TB diagnostics using a biomarker-class-driven framework, covering host-response biomarkers (IFN-γ and TNF-α), pathogen-derived antigens (ESAT6, CFP10, CFP10-ESAT6, MPT64, Ag85, HspX and LpqH), cell-wall signatures and whole-cell markers (LAM and whole cell Mtb), and genomic markers (Mtb DNA and IS6110). Through structured comparison of recognition elements, biointerface designs, signal amplification strategies, electrochemical techniques, matrices, and validation levels, this review identifies the most promising technical approaches for different TB biomarker classes. It further highlights key translational bottlenecks, including limited clinical validation, buffer-based testing, complex multistep amplification, redox-probe dependence, matrix fouling, and insufficient evidence of manufacturability. This review therefore provides practical guidance for developing electrochemical TB biosensors that are analytically sensitive, clinically relevant, and suitable for decentralized diagnostic applications.

Biosensing Techniques

Metal-organic frameworks nanozyme-integrated portable microneedle patch for visual bacterial monitoring in meat.

Foodborne microbial contamination is a major global health concern, with conventional methods often being time-consuming and complex. Herein, we developed a novel portable biosensor by integrating microneedle patch technology and a metal-organic framework (Fe/Cu-NBDC MOF) nanozyme, enabling rapid, on-site, visual detection of bacteria in meat. The sensing system works by encapsulating aptamer-functionalized MOF nanozymes within a hydrogel patch, where their catalytic sites are initially blocked by the aptamer. In the presence of Staphylococcus aureus (S. aureus) as the target, the specific aptamer's binding to bacteria exposes numerous catalytic sites, further activating the chromogenic reaction of the tetramethylbenzidine‑hydrogen peroxide (TMB-H₂O₂) system, enabling visual detection of S. aureus. The biosensor demonstrates a detection limit of 82 CFU/mL with excellent specificity to successfully apply to commercial mutton. By integrating sampling, enrichment, and visual detection into a single compact device, this platform offers a practical, efficient solution for rapid on-site screening of foodborne pathogens.

Biosensing Techniques

Determination of the affinity and kinetic constants for the interaction between the human virus echovirus 11 and its cellular receptor, CD55.

The biochemical properties of the molecular interactions mediating viral-cell recognition are poorly characterized. In this study, we use surface plasmon resonance to study the affinity and kinetics of the interaction of echovirus 11 with its cellular receptor decay-accelerating factor (CD55). As reported for interactions between cell-cell recognition molecules, the interaction has a low affinity (KD approximately 3.0 microM) as a result of a very fast dissociation rate constant (kon approximately 10(5) M-1.s-1, koff approximately 0.3 s-1). This contrasts with the interaction of soluble ICAM-1 (sICAM-1, CD54) with human rhinovirus 3 which has been reported to have a similar affinity but 10(2)-10(3)-fold slower kinetics (Casasnovas, J. M., and Springer, T. A. (1995) J. Biol. Chem. 270, 13216-13224). The extracellular portion of decay-accelerating factor comprises four short consensus repeat domains (domains 1-4) and a mucin-like stalk. By comparison of the binding affinity for echovirus 11 of various fragments of decay-accelerating factor, we are able to conclude that short consensus repeat domain 3 contributes approximately 80% of the binding energy.