Search PubMed⌕ Search

PubMed · 13640213

[Comparative studies on labor acceleration].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G OEHLERT, W HOECHST. 1959. [Comparative studies on labor acceleration].. https://pubmed.ncbi.nlm.nih.gov/13640213/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Numerical analysis of maximal bat performance in baseball.

Metal baseball bats have been experimentally demonstrated to produce higher ball exit velocity (BEV) than wooden bats. In the United States, all bats are subject to BEV tests using hitting machines that rotate the bat in a horizontal plane. In this paper, a model of bat-ball impact was developed based on 3-D translational and rotational kinematics of a swing performed by high-level players. The model was designed to simulate the maximal performance of specific models of a wooden bat and a metal bat when swung by a player, and included material properties and kinematics specific to each bat. Impact dynamics were quantified using the finite element method (ANSYS/LSDYNA, version 6.1). Maximum BEV from both a metal (61.5 m/s) and a wooden (50.9 m/s) bat exceeded the 43.1 m/s threshold by which bats are certified as appropriate for commercial sale. The lower BEV from the wooden bat was attributed to a lower pre-impact bat linear velocity, and a more oblique impact that resulted in a greater proportion of BEV being lost to lateral and vertical motion. The results demonstrate the importance of factoring bat linear velocity and spatial orientation into tests of maximal bat performance, and have implications for the design of metal baseball bats.

Acceleration↗

Lightweight low-profile nine-accelerometer package to obtain head angular accelerations in short-duration impacts.

Despite recognizing the importance of angular acceleration in brain injury, computations using data from experimental studies with biological models such as human cadavers have met with varying degrees of success. In this study, a lightweight and a low-profile version of the nine-accelerometer system was developed for applications in head injury evaluations and impact biomechanics tests. The triangular pyramidal nine-accelerometer package (PNAP) is precision-machined out of standard aluminum, is lightweight (65 g), and has a low profile (82 mm base width, 35 mm vertex height). The PNAP assures accurate orthogonal characteristics because all nine accelerometers are pre-aligned and attached before mounting on a human cadaver preparation. The feasibility of using the PNAP in human cadaver head studies is demonstrated by subjecting a specimen to an impact velocity of 8.1 m/s and the resultant angular acceleration peaked at 17 krad/s2. The accuracy and the high fidelity of the PNAP device at high and low angular acceleration levels were demonstrated by comparing the PNAP-derived angular acceleration data with separate tests using the internal nine-accelerometer head of the Hybrid III anthropomorphic test device. Mounting of the PNAP on a biological specimen such as a human cadaver head should yield very accurate angular acceleration data.

Acceleration↗

Consequences of forward translation of the point of force application for the mechanics of running.

In running humans, the point of force application between the foot and the ground moves forwards during the stance phase. Our aim was to determine the mechanical consequences of this 'point of force translation' (POFT). We modified the planar spring-mass model of locomotion to incorporate POFT, and then compared spring-mass simulations with and without POFT. We found that, if leg stiffness is adjusted appropriately, it is possible to maintain very similar values of peak vertical ground reaction force (GRF), stance time, contact length and vertical centre of mass displacement, whether or not POFT occurs. The leg stiffness required to achieve this increased as the distance of POFT increased. Peak horizontal GRF and mechanical work per step were lower when POFT occurred. The results indicate that the lack of POFT in the traditional spring-mass model should not prevent it from providing good predictions of peak vertical GRF, stance time, contact length and vertical centre of mass displacement in running humans, if an appropriate spring stiffness is used. However, the model can be expected to overestimate peak horizontal GRF and mechanical work per step. When POFT occurs, the spring stiffness in the traditional spring-mass model is not equivalent to leg stiffness. Therefore, caution should be exercised when using spring stiffness to understand how the musculoskeletal system adapts to different running conditions. This can explain the contradictory results in the literature regarding the effect of running speed on leg stiffness.

Acceleration↗