Search PubMed⌕ Search

PubMed · 13526686

A micro-electrophoretic method.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J KOHN. 1958-03-22. A micro-electrophoretic method.. https://doi.org/10.1038/181839a0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optical trapping microfabrication with electrophoretically delivered particles inside glass capillaries.

We have developed a new technique for rapid microfabrication that uses electrophoretically delivered particles and an optical trap. The material particles, micrometer- and nanometer-sized polystyrene beads in aqueous solution, are continuously delivered to an optical trap by means of the electrophoretic effect inside glass capillaries or similar microstructures. The optical trap is used to manipulate and deposit the polystyrene beads onto a substrate. The continuous, on-demand delivery of particles allows for microfabrication in two and three dimensions with high speed and high efficiency and without material waste. This new technique has many potential applications in microelectronics and biotechnology.

Electrophoresis↗

Advantages and limitations of coupling isotachophoresis and comprehensive isotachophoresis-capillary electrophoresis to time-of-flight mass spectrometry.

Capillary isotachophoresis (ITP) and comprehensive isotachophoresis-capillary electrophoresis (ITP-CE) were successfully coupled to electrospray ionization (ESI) orthogonal acceleration time-of-flight mass spectrometry (TOF-MS) using angiotensin peptides as model analytes. The utility of ITP-TOF-MS and ITP-CE-TOF-MS for the analysis of samples containing analyte amounts sufficient to form flat-top ITP zones (30 microM) as well as for samples with trace analyte amounts (0.3 microM) was studied. Separations were performed in 150 microm internal diameter (I.D.) capillaries for the ITP experiments, and in 200 microm I.D. (ITP) and 50 microm I.D. (CE) capillaries for ITP-CE experiments. The fused-silica columns were coated with poly(vinyl alcohol) to suppress electroosmotic flow that can disrupt ITP zone profiles. The sample loading capacity in both ITP and comprehensive ITP-CE was greatly enhanced (up to 10 microl) compared with typical nanoliter-sized injection volumes in CE. It was concluded that ITP-TOF-MS alone was adequate for the separation and detection of high concentration samples. The outcome was different at lower analyte concentrations where mixed zones or very sharp peaks formed. With formation of mixed zones, ion suppression and discrimination could occur, complicating quantitative determination of the analytes. This problem was effectively overcome by inserting a CE capillary between the ITP and TOF-MS. In such an arrangement, samples were preconcentrated in the high load WTP capillary and then injected into a CE capillary where they were separated into non-overlapping peaks prior to their detection by TOF-MS. The advantage of this comprehensive arrangement, which we have described previously, is that there is no need to discard portions of the sample in order to avoid overloading of the CE capillary. The whole sample is analyzed by multiple injections from ITP to CE. Thus, this method can be used for the analysis of complex samples with wide ranges of component concentrations.

Electrophoresis↗

Isotachophoretic determination of stability constants of Ho and Y complexes with diethylenetriaminepentaacetic acid and 1,4,7,10-tetraazadodecane-N,N',N'',N'''-tetraacetic acid.

The method of capillary isotachophoresis with conductivity detection was applied for the determination of the physico-chemical characteristics (conditional stability constants log beta') of holmium and yttrium complexes with DTPA (diethylenetriaminepentaacetic acid) and DOTA (1,4,7,10-tetraazadodecane-N,N',N'',N'''-tetraacetic acid). The log beta' determination is based on the linear relation between the stability constants of lanthanide-DTPA (lanthanide-DOTA) complexes and the reduction of the zone of the complex owing to the bleeding phenomena (liberating free metal ion). The stability constants calculated using this relationship are comparable with the literary data obtained by other methods for both holmium (log beta'(Ho-DTPA)=21.9, log beta'(Ho-DOTA)=24.5) and yttrium complexes (log beta'(Y-DTPA)=21.2, log beta'(Y-DOTA)=24.4). Capillary isotachophoresis was applied for the determination of the optimum composition of the reaction mixture (metal:ligand ratio) as well.

Electrophoresis↗