Search PubMed⌕ Search

PubMed · 13520161

[Currently applied lung function tests].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A MINETTE. 1957. [Currently applied lung function tests].. https://pubmed.ncbi.nlm.nih.gov/13520161/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Inulin is an ideal substrate for a hydrogen breath test to measure the orocaecal transit time.

BACKGROUND: A better substrate is needed for a hydrogen breath test to measure the orocaecal transit time. The currently used substrate, lactulose, accelerates the orocaecal transit time by increasing the osmolality of the gut contents. The recently developed lactose 13C-ureide breath test is reliable, but a hydrogen breath test is preferred, as it allows the simultaneous investigation of the digestion and absorption of nutrients by means of 13C-labelled compounds. METHODS: The usefulness of different types of inulin as a substrate for a hydrogen breath test was studied. Raftilin HP (>99% inulin with a degree of polymerization of between 5 and 60 and <0.5% glucose, fructose and sucrose) was further evaluated and compared with lactulose with regard to its effects on gastric emptying and the digestion of protein and lipids. RESULTS: A good correlation was found between the orocaecal transit times using Raftilin HP (338 min; interquartile range, 300-383 min) and lactose 13C-ureide (353 min; interquartile range, 285-375 min) (r=0.85; P<0.001). The administration of 5 or 10 g Raftilin HP had no influence on the orocaecal transit time, whereas lactulose significantly shortened the orocaecal transit time. Neither inulin nor lactulose had a significant influence on gastric emptying or protein or lipid assimilation. CONCLUSION: Raftilin HP is an ideal substrate for a hydrogen breath test to measure the orocaecal transit time.

Breath Tests↗

Application of solid-phase microextraction and gas chromatography-mass spectrometry to the determination of volatile organic compounds in end-exhaled breath samples.

Analysis of exhaled air is of particular interest as an indicator of health as well as a tool for the diagnosis of diseases. It is also a very attractive procedure for the biological control of the exposition to hazardous solvents. This kind of analysis presents numerous advantages over other methods, the most important being that it is not an invasive procedure and, therefore, it is well accepted and can be applied to a wide range of compounds. Furthermore, the analysis is simplified since the matrix is less complex that in the case of blood or urine. In spite of these obvious advantages and the good results obtained, analysis of exhaled air is not in daily use, probably due to the fact that there are no normalized systems of sampling, thus making the interpretation of the results difficult. In this paper, a method for the determination of tetrachloroethylene in exhaled air using solid-phase microextraction is presented. This method, which can be applied to other volatile organic compounds, was developed with special emphasis of end-exhaled breath sampling. The sample is collected in a glass tube whose ends are closed once the exhalation is finished. The tube has an orifice sealed with a septum through which the fiber is inserted. Then, the fiber is desorbed in the injector of a gas chromatograph and the analysis is accomplished using mass spectrometry for the identification and quantification of the components. The proposed system avoids the need of complex sampling equipment and allows analysis of the alveolar fraction. Additionally, the system is economical and easy to handle, thus facilitating the development of normalized methods and its routine use in field studies.

Breath Tests↗

Exhaled breath condensates: a potential novel technique for detecting aspiration.

There is an urgent need for diagnostic procedures that can detect aspiration of oral and gastrointestinal (GI) secretions into the respiratory tract. Current approaches are limited by poor sensitivity and specificity. These techniques include (1) adding indicators to feedings; (2) recovery of lipid-filled macrophages in respiratory secretions; (3) measurement of changes in the pH of the upper GI and respiratory tracts; (4) endoscopic visualization of reflux events; and (5) measurement of increased glucose concentrations in respiratory secretions. Ideally, specific markers from various sites in the oral and GI tracts might be discovered in respiratory secretions, but conventional bronchoalveolar lavage for sampling respiratory secretions is not practical and involves some risk. Noninvasive measurements of indicators in the exhaled breath condensates could be used to detect aspiration, but a number of theoretical and practical aspects of such studies must be considered before this approach can be applied to the problem of aspiration.

Breath Tests↗