Search PubMedSearch

PubMed · 1308213

Retention for a removable partial denture.

Abstract

This article addresses the complex nature of retention in a removable partial denture. Retentive features range from magnets and springs to clips, clasps, and interfacial surface tension. The retentive quality of an extracoronal clasp varies with the alloy, physical form, location on the abutment, and positional relationship to other elements. Surveying to identify both occlusogingival and mesiodistal undercuts when the path of random dislodging forces are not definitely controlled is needed for effective retention. Augmentation of ineffective retention in existing clasps should concentrate on methods of deepening the undercut or increasing the suprabulge. Tightening of clasps already in contact with a tooth frequently produces adverse changes.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D L Johnson. 1992. Retention for a removable partial denture.. https://doi.org/10.1111/j.1532-849x.1992.tb00420.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Implant position record and implant position cast: minimizing errors, procedures and patient visits in the fabrication of the milled-bar prosthesis.

This article describes a new rationale and method involved in the fabrication of a patient detachable prosthesis supported by a milled bar. This simple procedure improves prosthesis retention. The overdenture is processed directly over a milled bar, which provides an intimate relation between the bar and the acrylic resin denture base to create resistance against rotational and lateral forces acting on the prosthesis. Incorporating simple and predictable attachments, with low maintenance needs, controls resistance to dislodgment along the path of insertion of the prosthesis. The concepts used in the fabrication of the milled bar include an implant position record (IPR) and an implant position cast (IPC) to reduce the need for time-consuming procedures, such as sectioning the cast bar and soldering it to make it fit the abutments. This procedure also reduces the number of patient visits required of the completion of the prosthesis.

Dental Abutments

Proximal plate in conventional circumferential cast clasp retention.

Improper guiding planes are commonly used with conventional removable partial denture cast clasps. Short guiding planes with improper proximal plates decrease retention and cause repetitive traumatic movement of abutments. This article discusses the importance of guiding planes and proximal plates for conventional tooth-supported removable partial dentures with circumferential clasp. The retention force of the clasps was analyzed geometrically. If the guiding plane is short or the prepared surface is oblique, the contact between the proximal plate and the guiding plane or oblique plane diminishes at an early stage, which results in reduction of retention. The guiding plane should be parallel to the path of insertion and must be of a certain length for adequate retention. An elongated proximal plate that is parallel to the path of insertion may compensate for retention deficiency when an adequate guiding plane cannot be prepared.

Dental Abutments

Dental implants. 7. Basic restorative techniques.

Some restorative techniques for implant supported restorations will be familiar to dentists used to providing conventional crown and bridgework. The differences and principles involved when using implants are identified.

Dental Abutments