Search PubMed⌕ Search

PubMed · 12851828

Error bands for the linear-quadratic dose-effect relation.

Abstract

Least square or maximum likelihood fits to the linear-quadratic dose-effect relation are common in experimental radiobiology and in radio-epidemiology. The fit procedure provides the estimates of the linear and the quadratic dose coefficients, a and b, as well as their standard errors, s(a) and s(b). The magnitude of the standard errors s(a) and s(b) is partly determined by the fact that-for a given data set-different parameter combinations (a, b) can produce rather similar fits, i.e. larger values of a can be roughly compensated by smaller values of b. The values s(a) and s(b) are, because of this interrelation, unsuitable to determine error bands of the dose-effect relation. The exact analysis accounts for the co-variance of the parameters, but it is rarely employed. To avoid the consideration of co-variances a simple parameter change is introduced here that replaces the dose-squared coefficient, b, by a+ bDelta. This term is the effect-to-dose ratio at the reference dose Delta, and can thus be termed reference slope. With the proper value of Delta-which is readily determined for a data set, and is 2 Gy for the dicentric chromosome data which are used as example-the two parameters initial slope, a, and reference slope are then orthogonal, i.e. there is no inter-dependence of the parameter values, and their uncertainties can be treated as independent. In the case of three-model parameters, e.g. the linear-quadratic model with an intercept term, c, the same type of parameter change can be applied to make both the first and the third parameter orthogonal to a. The curve fit is then performed conveniently with the standard computer routines, and parameter uncertainties are obtained that provide by simple error propagation the equations for the standard error or confidence bands of the dose-effect relation. Appendix A gives the numerical scheme.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A M Kellerer. 2003-07-08. Error bands for the linear-quadratic dose-effect relation.. https://doi.org/10.1007/s00411-003-0195-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optimal designs for radiation retention with poisson correlated response.

In this paper we describe a non-linear model with correlated observations which accounts for the elimination rate of radiation in the lung of individuals who have been exposed to an accidental intake at some time. The response is then modelled as a conditional Poisson distribution. When the leak is moderate or the size of the particles is large a theoretical justification of this assumption is given and D-optimal designs are computed.

Dose-Response Relationship, Radiation↗

Nanodosemeters based on gel scintillators.

The feasibility of a nanodosemeter based on a liquid scintillator cocktail of four components (ethoxylated nonylphenol, pseudocumene, water and a lipophilic mixture) is studied. The dosemeter can work in distinct gel phases, for which the radioactive substance can be confined inside aqueous nanoscale structures of different size. For water volumes ranging 0-15%, it results in a gel with micelles of 4 nm radius. For water volumes ranging 30-50%, the resulting liquid-crystal gel contains nanostructures of approximately 20 nm radius. The low-energy electron emission arising from the decay of (3)H and (55)Fe is counted in a commercial liquid-scintillation counting spectrometer for both homogeneous and gel samples. The counting efficiency gap between the two phases is used to compute the average energy deposited inside the micelle.

Dose-Response Relationship, Radiation↗

Stereotactic radiosurgery and radiation therapy for spinal tumors.

Spinal tumors constitute 15% of all CNS neoplasms. Radiation therapy can be administered for palliation of pain and spinal cord compression. However, the amount of radiation that can be administered is often limited by the tolerance of the spinal cord, especially in cases where prior radiation therapy has been given. Stereotactic radiosurgery and radiotherapy allow the delivery of a higher dose of radiation to spinal lesions, while limiting the spinal cord dose to below the tolerance level. These are technically demanding procedures and should be performed only when proper equipment and expertise are available. Data on spinal stereotactic radiosurgery and radiotherapy have emerged in recent years. This review summarizes the clinical applications of stereotactic radiosurgery and radiotherapy for spinal tumors.

Dose-Response Relationship, Radiation↗