Interpretative comments and reference ranges in EQA programs as a tool for improving laboratory appropriateness and effectiveness.

Abstract

INTRODUCTION: Laboratory information is generated when a meaning is given to certain data. This is usually achieved by comparing a laboratory test result with the reference range/decisional limit (RL), and by providing consultation for the interpretation of data, advice, and follow-up testing. AIM: In this paper, we investigate factors affecting the conversion of data into useful information with regard to biochemical markers of myocardial damage (CK-MB mass, myoglobin, and troponins), in view of their importance in detecting myocardial necrosis. Our aim was to report results obtained in order to verify the consensus between laboratories with reference to interpretative comments and the reference ranges/decisional limits added to clinical reports. METHODS: A questionnaire and simulated medical reports on three different patients were distributed to participants (94 laboratories) in the 2001 cycle of the External Quality Assessment (EQA). Moreover, we analysed 113 medical reports sent by laboratories during the most recent EQA cycle 2002, and checked the number of different RLs used, both independent and within the diagnostic system used. We also compared each laboratory result of a control sample, obtained in the 2002 cycle, with declared RL in order to verify the clinical significance of results ("normal" or "pathological") for troponin I and CK-MB. RESULTS: Our findings show that few laboratories regularly add interpretative comments to medical reports. On the contrary, they cooperate with clinicians who require consultation, advice, and information for the appropriate use of biochemical markers. There is a general consensus among participants regarding probable syndromes suggested by the interpretation of the same result and most laboratories also agree on further investigations to be carried out for several diseases. Concerning RL, the data demonstrate that numerous different RLs are used to report the results of the biochemical markers evaluated, both when considered independent of the diagnostic system used and within the diagnostic system used. DISCUSSION AND CONCLUSIONS: The biochemist does not have the opportunity to verify the efficacy of the interpretation that he/she provided. An audit of this activity is therefore required to allow the laboratory to monitor its own performance and to assure good practice. The evaluation of interpretative comments, through specific surveys, should be a prime objective of EQA organisers. Well-designed EQA programs can, moreover, support laboratories in establishing appropriate RL and in verifying the clinical significance of their results with respect to that of other laboratories. Our survey on interpretative comments and the analysis of the RLs further demonstrate how laboratory medicine can contribute to the objective evaluation of the patients' health status.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Laura Sciacovelli, Lorena Zardo, Sandra Secchiero, Martina Zaninotto, Mario Plebani. 2003-07-15. Interpretative comments and reference ranges in EQA programs as a tool for improving laboratory appropriateness and effectiveness.. https://doi.org/10.1016/s0009-8981(03)00188-8

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Bioluminescent immunoassay of thyrotropin and thyroxine using obelin as a label.

Solid-phase bioluminescent immunoassay of thyroid hormones, human thyrotropin (hTSH) and two forms of thyroxine (T4), whose determinations are vitally important for diagnostics of thyroid diseases and the efficiency of treatment, is described. The recombinant obelin, a Ca(2+)-regulated photoprotein originally derived from the luminous marine hydroid Obelia longissima, is employed as a bioluminescent label. To produce obelin conjugates with anti-hTSH, anti-T4 immunoglobulins (IgG), and T4, additional SH groups are introduced into the obelin molecule using Traut's reagent (2-iminothiolane) and then obelin possessing extra SH groups is conjugated with succinimidyl 4-(N-maleimidomethyl)-cyclohexane-1-carboxylate-activated IgGs or T4. The total yield of obelin conjugates determined by luminescent activity is 60-65% after all chemical and purification procedures. The obtained conjugates are stable to lyophilization and in solution for at least 9 months at 4 degrees C, with loss of activity not exceeding 10%. The application of obelin conjugates for determination of the hTSH, total T4, and free T4 in standard, control, and patient sera displays high sensitivity and reproducibility of results. The results of bioluminescent immunoassays are closely comparable to those obtained by the radioimmunoassay method (R=0.95-0.99).

Clinical Laboratory Techniques↗

Interlaboratory comparison of fetal male DNA detection from common maternal plasma samples by real-time PCR.

BACKGROUND: Analysis of fetal DNA from maternal plasma by PCR offers great potential for noninvasive prenatal genetic diagnosis. To further evaluate this potential, we developed and validated a standard protocol to determine whether fetal DNA sequences could be reproducibly amplified and measured across multiple laboratories in a common set of specimens. METHODS: Each of five participating centers in a National Institute of Child Health and Human Development consortium collected 20 mL of peripheral blood from 20 pregnant women between 10 and 20 weeks of gestation. The plasma fraction was separated according to a common protocol, divided, and frozen in five aliquots. One aliquot was shipped to each participating laboratory, where DNA was extracted according to a standard protocol. All plasma samples (n = 100) were then analyzed blindly for the presence and quantity of total DNA (GAPDH) and male fetal DNA (SRY) by real-time PCR. Genomic DNA was isolated from female and male cells at one center, quantified, and shipped to the others to serve as calibrators for GAPDH and SRY, respectively. RESULTS: The amplification of known quantities of DNA was consistent among all centers. The mean quantity of male DNA amplified from maternal plasma when the fetus was male ranged from 51 to 228 genome equivalents (GE)/mL. Qualitative concordance was found overall among centers. The sensitivity of the assay for detection of male DNA when the fetus was male varied from 31% to 97% among centers. Specificity was more consistent (93-100%) with only four false-positive results obtained across the entire study. CONCLUSIONS: All centers were able to consistently amplify frozen and shipped DNA. The PCR procedure used here is reliable and reproducible. Centers that extracted and amplified more DNA per milliliter of maternal plasma had superior sensitivities of Y chromosome sequence detection. The specificity of the assay was more consistent among centers. A robust and thoroughly optimized protocol for the extraction of DNA from maternal plasma is needed to make testing of fetal DNA in maternal plasma a clinically relevant analytical tool.

Clinical Laboratory Techniques↗