Search PubMed⌕ Search

PubMed · 12708640

Screening CT colonography.

Abstract

CT colonography (Virtual Colonoscopy) was first introduced in 1994 as a novel imaging technique for the detection of colorectal polyps and cancer. It is currently proposed as a new screening tool for colorectal carcinoma that may be more acceptable to patients than current methods. There are a growing number of published studies evaluating all aspects of CT colonography, including technique, imaging displays, interpretation methods, patient acceptance, and lesion detection accuracy. While there are multiple studies that have found excellent CT colonography results for the detection of larger polyps in high risk or symptomatic patient cohorts, there are very few published studies evaluating the performance of CT colonography in asymptomatic screening patients. Although we do not have the results of large, randomized, controlled trials documenting the performance of CT colonography in screening-type patients, this technique is currently employed at some sites as a screening tool for colorectal carcinoma. Thus, CT colonography has become a part of the controversy surrounding total body CT screening. In this article, the current techniques for colonic preparation and distention will be discussed, as well as the optimum CT protocol, and the recommended use of image displays for time-efficient interpretation. The results of the larger and newer studies will be presented, as well as some of the current clinical uses of CT colonography. Issues specific to the use of CT colonography as a screening test will also be discussed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Judy Yee. 2003. Screening CT colonography.. https://doi.org/10.1016/s0887-2171(03)90021-7

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Magnetic resonance colonography vs computed tomography colonography for the diagnosis of colorectal cancer: an indirect comparison.

OBJECTIVE: The primary aim of this study was to use meta-regression techniques to compare the diagnostic accuracy of computed tomography colonography (CTC) and magnetic resonance colonography (MRC), compared with conventional colonoscopy for patients presenting with colorectal cancer (CRC). METHOD: Quantitative meta-analysis was performed using prospective studies reporting comparative data between CTC and MRC individually to conventional colonoscopy. Study quality was assessed and sensitivities, specificities, diagnostic odds ratios (DOR) were calculated. Summary receiver operating characteristic (SROC) curves and sensitivity analysis were utilized. Meta-regression was used to indirectly compare the two modalities following adjustment for patient and study characteristics. RESULTS: Overall sensitivity and specificity for CTC (0.96, 95% CI 0.92-0.99; 1.00, 95% CI 0.99-1.00 respectively) and MRC (0.91, 95% CI 0.79-0.97; 0.98, 95% CI 0.96-0.99 respectively) for the detection of CRC was similar. Meta-regression analysis showed no significant difference in the diagnostic accuracy of both modalities (beta=-0.64, P=0.37 and 95% CI of 0.12-2.39). Both tests showed high area under the SROC curve (CTC=0.99; MRC=0.98), with high DORs (CTC=1461.90, 95% CI 544.89-3922.30; MRC=576.41, 95% CI 135.00-2448.56). Factors that enhanced the overall accuracy of MRC were the use intravenous contrast, faecal tagging and exclusion of low-quality studies. No factors improved diagnostic accuracy from CTC except studies with more than 100 patients (AUC=1.00, DOR=2938.35, 95%CI 701.84-12 302.91). CONCLUSION: This meta-analysis suggested that CTC and MRC have similar diagnostic accuracy for detecting CRC. Study quality, size and intravenous/intra-luminal contrast agents affect diagnostic accuracies. For an exact comparison to be made, studies evaluating CTC, MRC and colonoscopy in the same patient cohort would be necessary.

Colonography, Computed Tomographic↗

Development of a synthetic phantom for the selection of optimal scanning parameters in CAD-CT colonography.

The aim of this paper is to present the development of a synthetic phantom that can be used for the selection of optimal scanning parameters in computed tomography (CT) colonography. In this paper we attempt to evaluate the influence of the main scanning parameters including slice thickness, reconstruction interval, field of view, table speed and radiation dose on the overall performance of a computer aided detection (CAD)-CTC system. From these parameters the radiation dose received a special attention, as the major problem associated with CTC is the patient exposure to significant levels of ionising radiation. To examine the influence of the scanning parameters we performed 51 CT scans where the spread of scanning parameters was divided into seven different protocols. A large number of experimental tests were performed and the results analysed. The results show that automatic polyp detection is feasible even in cases when the CAD-CTC system was applied to low dose CT data acquired with the following protocol: 13 mAs/rotation with collimation of 1.5 mm x 16 mm, slice thickness of 3.0mm, reconstruction interval of 1.5 mm, table speed of 30 mm per rotation. The CT phantom data acquired using this protocol was analysed by an automated CAD-CTC system and the experimental results indicate that our system identified all clinically significant polyps (i.e. larger than 5 mm).

Colonography, Computed Tomographic↗