Search PubMed⌕ Search

PubMed · 12621338

Vestibular dysfunction after cochlear implantation.

Abstract

OBJECTIVE: To determine the prevalence, symptom characteristics, and potential risk factors for vestibular symptoms after cochlear implantation. STUDY DESIGN: Case-control study design embedded within an ongoing cohort of patients undergoing implantation. SETTING: Academic medical center cochlear implant research program funded by the National Institutes of Health. PATIENTS: Seventy five eligible consecutive patients undergoing cochlear implantation. INTERVENTION: Medical record review. MAIN OUTCOME MEASURE: Recorded symptoms of vestibular symptoms after cochlear implantation. Subjects with vestibular symptoms were considered case subjects; those without vestibular symptoms were considered control subjects. RESULTS: Twenty-nine of 75 (39%) patients experienced dizziness postoperatively. Four patients experienced a single, transient acute vertigo attack occurring less than 24 hours after surgery. The majority, 25 patients, experienced delayed, episodic onset of vertigo. The median (interquartile range) time of delayed onset was 74 (26-377) days after implantation. Delayed dizziness manifested as spontaneous episodic or positional vertigo. Preoperative dizziness, age at implantation, and age at onset of hearing loss were significantly greater in the dizzy group. Preoperative electronystagmography did not differentiate between groups. CONCLUSIONS: Thirty-nine percent (29/75) of subjects with implants were dizzy after implantation. The majority of subjects experienced dizziness in a delayed episodic fashion. Dizziness was not related to implant activation. It seemed that delayed dizziness was not related to immediate surgical intervention but could result from chronic changes occurring in the inner ear; there was some suggestion this could take the form of endolymphatic hydrops.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Manuela Fina, Margaret Skinner, Joel A Goebel, Jay F Piccirillo, J Gail Neely, Owen Black. 2003. Vestibular dysfunction after cochlear implantation.. https://doi.org/10.1097/00129492-200303000-00018

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of acute pain crisis on exhaled nitric oxide levels in children with sickle cell disease.

Exhaled nitric oxide (FE(NO)) has been shown to be decreased in children with sickle cell disease. We sought to evaluate the effect of sickle cell vaso-occlusive crisis (VOC) on FE(NO) levels. We measured FE(NO) levels in 42 children with sickle cell disease, 29 in their baseline health and 13 during an acute VOC. There was no difference in FE(NO) levels between children at baseline (15.12 +/- 9.32 ppb) and those during an acute VOC (15.68 +/- 7.26 ppb; P = 0.794). FE(NO) is not a useful marker of acute VOC in children with sickle cell disease.

Acute Disease↗

[Megadolichobasilar anomaly causing acute deafness with vertigo].

Megadolichobasilar anomaly, a dilatant arteriopathy of the basilar artery attributable to chronic arterial hypertension, can cause cranial nerve compression syndromes of the cerebellopontine angle or infarcts of the vertebrobasilar circulation. In this paper, we report on a patient with known megadolichobasilar anomaly and a partially thrombosed fusiform aneurysm of the basilar artery, who presented with acute-onset vertigo and subsequent deafness due to thromboembolic occlusion of the labyrinthine artery. Because of the vascular origin of the patient's symptoms, his vertigo disappeared over time while the deafness persisted.

Acute Disease↗

Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

Acute Disease↗