Search PubMed⌕ Search

PubMed · 12539116

Solidifying the solid angle.

Abstract

This paper evaluates the position of the solid angle in its application to modeling in electrocardiology. Particular attention is paid to the use of the solid angle for linking cardiac electric activity to the potentials observed on the body surface. In this application, the solid angle is a dominant factor in the expression of the sources during depolarization known as the uniform double layer. In the related equivalent double layer model, the contributions of the elementary sources are also expressed in terms of solid angles, their strength not being uniform. A recently developed theory allows the equivalent double layer to be applied to both depolarization and repolarization.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A van Oosterom. 2002. Solidifying the solid angle.. https://doi.org/10.1054/jelc.2002.37176

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Computer analysis of multichannel ECG.

Multichannel electrocardiography (MECG) is an extension of the conventional electrocardiography that is aimed at refining the non-invasive characterisation of cardiac activity. Body surface mapping is a graphical presentation of cardiac activity as measured from the body surface. Body surface maps can show the distribution of the potential at a selected moment in time or over a specified time interval. A new family of maps, based on the characteristics derived from the complete analysed beat, is described. Some new computer supported methods, which are able to calculate automatically different temporal maps, are proposed. MECG measurements can be seen in this context as a powerful research and clinical tool for improving the resolution of cardiac measurements.

Body Surface Potential Mapping↗

Body surface mapping of cardiac activity after partial left ventriculectomy.

MECG measurements were performed using 35 electrodes in 10 patients operated with partial left ventriculectomy (PLV). Body surface ECG signals were recorded and five measurements were done: prior to PLV, second, third, fourth and fifth postoperative day. This work was concentrated on the following mapping methods: average isopotential ST segment maps (STM), QRS interval isointegral maps (QRM) and isochronal activation maps (IAM). STMs of the patients show a great positive area (elevation) over the anterior aspect of the heart and a great negative area (depression) over the lateral and posterior aspect of the heart before the operation. After the operation, the ST elevation over the anterior, lateral and posterior aspect of the heart was reduced. A substantial positive value over the excised area of the heart was present also on the end of the postoperative monitoring interval. Minimal and maximal values of the QRMs were smaller and also show some kind of normalisation. The area of the left ventricle, where PLV was performed, was carefully analysed for any changes of activation time for different heart regions. IAMs indicate that the start of the first activation was quite stable and in accordance with the position of the QRMs minimum.

Body Surface Potential Mapping↗