Search PubMed⌕ Search

PubMed · 12530820

Comprehensive solid-phase extraction method for persistent organic pollutants. Validation and application to the analysis of persistent chlorinated pesticides.

Abstract

The Centers for Disease Control and Prevention (CDC) is involved in many epidemiological studies regarding the measurement of chlorinated pesticides and polychlorinated biphenyls in specimens obtained from humans. In addition to these commonly determined analytes, there is a need to include additional persistent organic pollutants (POPs) in our analyses, which further stresses the analyses because sample volumes remain small. Thus, a single method of analysis for all POPs in human serum is needed. CDC has recently developed a semiautomated and comprehensive solid-phase extraction method for POPs. The method is comprehensive since it was optimized for the extraction of many different POP compound classes. We then developed a purification and fractionation scheme that allows (a) separation of different compound classes by particular functionalities and (b) purification of those fractions to remove coextracted interferences. This paper describes the first step in the semiautomated comprehensive extraction and multiple fractionation method developed by CDC for monitoring POPs. In this paper, we validate the analysis of the persistent chlorinated pesticides, a compound class difficult to examine because of their structural diversity, in human plasma. The method was validated against an existing CDC method by using a spiked quality-control serum pool. The concentrations determined for all analytes using both methods were within 2%-14% relative standard deviations. A multilevel (i.e., 3-4 point) matrix spike showed good linearity for the analytes tested (r2 = 0.978-0.999). The method was then applied to 40-year-old archived plasma samples for the quantitative analysis of selected chlorinated pesticides. Mean recoveries of the 13C-labeled internal quantification standards ranged from 64% to 123% for the 11 monitored pesticides. The overall method proved to be robust by handling old coagulated plasma samples. It allowed faster throughput of samples than our previous methods and provided cleaner samples with less frequent interferences or background as analyzed by high-resolution mass spectrometry. The method represents a preliminary step in establishing an automated, comprehensive multiresidue analysis method for POPs in human serum.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Courtney D Sandau, Andreas Sjödin, Mark D Davis, John R Barr, Vincent L Maggio, Alyson L Waterman, Kerry E Preston, James L Preau, Dana B Barr, Larry L Needham, Donald G Patterson. 2003-01-01. Comprehensive solid-phase extraction method for persistent organic pollutants. Validation and application to the analysis of persistent chlorinated pesticides.. https://doi.org/10.1021/ac026121u

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Repacking the Core of T4 lysozyme by automated design.

Automated protein redesign, as implemented in the program ORBIT, was used to redesign the core of phage T4 lysozyme. A total of 26 buried or partially buried sites in the C-terminal domain were allowed to vary both their sequence and side-chain conformation while the backbone and non-selected side-chains remained fixed. A variant with seven substitutions ("Core-7") was identified as having the most favorable energy. The redesign experiment was repeated with a penalty for the presence of methionine residues. In this case the redesigned protein ("Core-10") had ten amino acid changes. The two designed proteins, as well as the constituent single mutants, and several single-site revertants were over-expressed in Escherichia coli, purified, and subjected to crystallographic and thermal analyses. The thermodynamic and structural data show that some repacking was achieved although neither redesigned protein was more stable than the wild-type protein. The use of the methionine penalty was shown to be effective. Several of the side-chain rotamers in the predicted structure of Core-10 differ from those observed. Rather than changing to new rotamers predicted by the design process, side-chains tend to maintain conformations similar to those seen in the native molecule. In contrast, parts of the backbone change by up to 2.8A relative to both the designed structure and wild-type. Water molecules that are present within the lysozyme molecule were removed during the design process. In the redesigned protein the resultant cavities were, to some degree, re-occupied by side-chain atoms. In the observed structure, however, water molecules were still bound at or near their original sites. This suggests that it may be preferable to leave such water molecules in place during the design procedure. The results emphasize the specificity of the packing that occurs within the core of a typical protein. While point substitutions within the core are tolerated they almost always result in a loss of stability. Likewise, combinations of substitutions may also be tolerated but usually destabilize the protein. Experience with T4 lysozyme suggests that a general core repacking methodology with retention or enhancement of stability may be difficult to achieve without provision for shifts in the backbone.

Automation↗

Development, principles, and applications of automated ice fabric analyzers.

We review the recent development of automated techniques to determine the fabric and texture of polycrystalline ice. The motivation for the study of ice fabric is first outlined. After a brief introduction to the relevant optical concepts, the classic manual technique for fabric measurement is described, along with early attempts at partial automation. Then, the general principles behind fully automated techniques are discussed. We describe in some detail the similarities and differences of the three modern instruments recently developed for ice fabric studies. Next, we discuss briefly X-ray, radar, and acoustic techniques for ice fabric characterization. We also discuss the principles behind automated optical techniques to measure fabric in quartz rock samples. Finally, examples of new applications that have been facilitated by the development of the ice fabric instruments are presented.

Automation↗

Automated large-volume sample stacking procedure to detect labeled peptides at picomolar concentration using capillary electrophoresis and laser-induced fluorescence detection.

We have developed an automated large-volume sample stacking (LVSS) procedure to detect fluorescein isothiocyanate-labeled peptides in the picomolar range. The injection duration is 10 min at 50 mbar to fill 62% of the capillary volume to the detection cell. The calculated limit of detection (S/N=3), filling 1% of the capillary volume, is 74 pM for bradykinin and 45 pM for L-enkephalin with samples diluted in water and analyzed in a 50 mM borate buffer, pH 9.2. With the automated LVSS system, the limits of detection are 7 pM for bradykinin, 3 pM for L-enkephalin and 2 pM for substance P. LVSS is shown to be quantitative from 500 to 10 pM.

Automation↗