Laminar-flow-based separations at the microscale.

Abstract

The natural separation maintained by microfluidic flows is employed as the basis of a particle/cell sorting device. This method of separating particulate suspensions exploits the inherent laminar nature of microscale fluid dynamics and incorporates applied fields and image cytometry to enable sorting based upon any visually identifiable difference between colloid-sized cells or particles. This technique may be used to easily isolate, separate, sort, or enrich virtually any suspension of microscale biological or colloidal particles within a microfluidic system. The entire footprint of the device described here is less than 0.01 mm(2), allowing it to be readily incorporated within highly integrated micro total analysis systems (microTAS).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

John Oakey, Josh Allely, David W M Marr. Laminar-flow-based separations at the microscale.. https://doi.org/10.1021/bp0256216

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Isolation of monocytes from human peripheral blood using immuno-affinity expanded-bed adsorption.

A novel technique for the separation of monocytes from human peripheral blood preparations has been developed. The technique is based on the use of expanded-bed adsorption and a solid perfluorocarbon derivatized with avidin or streptavidin for the indirect positive or negative capture of cells labeled with biotinylated monoclonal antibodies. The perfluorocarbon support was prepared and characterized and the contactor design and operating conditions, that enable cells to be selectively isolated, were investigated. Experiments consisted of applying an immunolabeled pulse of 1 x 10(8) peripheral blood mononuclear cells (PBMCs), isolated by density gradient centrifugation, directly onto a refrigerated expanded bed. The major cell types remaining were T-lymphocytes, B-lymphocytes, and monocytes. Monocytes could be positively adsorbed, following labeling with anti-CD14 mAb, with a clearance of up to 89% and a depletion factor of 7.6. They could also be "eluted" using mechanical shear, with a 77% yield of the applied cells at a purity of 90% and >/= 65% viability. Negative isolation of monocytes, following labeling of the other cells present with anti-CD2, CD7, CD16, CD19, and CD56 mAbs, resulted in lymphocyte depletions of up to 81% with a monocyte enrichment factor of 3.8 and purity of 71%. The monocyte viability in the flowthrough was assessed to be > 95%. This combination of expanded-bed adsorption and fluidizable affinity supports shows significant potential for the intensification of cell separations.

Cell Separation↗

Measurement of DNA breaks and oxidative damage in polymorphonuclear and mononuclear white blood cells: a novel approach using the comet assay.

DNA damage is thought to play a relevant role in degenerative diseases and aging. Therefore, measuring DNA damage in living cells without artifacts is a critical issue, especially with very sensitive methods, such as the comet assay, which can detect very low levels of DNA damage. We show here that the procedures of cell subtype isolation increase DNA damage measured in human white blood cells (WBC) with the comet assay. We describe a novel and simple method to measure DNA strand breaks and oxidative damage separately in polymorphonuclear and mononuclear leukocytes, using whole blood without previous cell isolation. This method can be useful for measuring DNA damage in different subtypes of human peripheral leukocytes, avoiding the artifacts and the time involved in the cell separation procedures.