Search PubMed⌕ Search

PubMed · 12454639

Sharper tools and simpler methods.

Abstract

In this issue of The Chipping Forecast, we are witnesses to the adolescence of a class of technologies that are enabling us to monitor globally aspects of gene expression. Chip-based technologies are specific examples of a more general trend toward the implementation of systematic and comprehensive methods in biological research. We need to recognize, however, that these technologies, while seductive, can sometimes be corruptive. In other words, we must guard against committing the mortal sin of genomics by confusing throughput with output, which too often blurs the distinction between data and knowledge. Instead, we must maintain the necessary focus to achieve an ever-more operational understanding of all the molecular components and the interactions that define a cell or an organism.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Geoffrey M Duyk. 2002. Sharper tools and simpler methods.. https://doi.org/10.1038/ng1027

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Impact of surface chemistry and blocking strategies on DNA microarrays.

The surfaces and immobilization chemistries of DNA microarrays are the foundation for high quality gene expression data. Four surface modification chemistries, poly-L-lysine (PLL), 3-glycidoxypropyltrimethoxysilane (GPS), DAB-AM-poly(propyleminime hexadecaamine) dendrimer (DAB) and 3-aminopropyltrimethoxysilane (APS), were evaluated using cDNA and oligonucleotide sub-arrays. Two un-silanized glass surfaces, RCA-cleaned and immersed in Tris-EDTA buffer were also studied. DNA on amine-modified surfaces was fixed by UV (90 mJ/cm(2)), while DNA on GPS-modified surfaces was immobilized by covalent coupling. Arrays were blocked with either succinic anhydride (SA), bovine serum albumin (BSA) or left unblocked prior to hybridization with labeled PCR product. Quality factors evaluated were surface affinity for cDNA versus oligonucleotides, spot and background intensity, spotting concentration and blocking chemistry. Contact angle measurements and atomic force microscopy were preformed to characterize surface wettability and morphology. The GPS surface exhibited the lowest background intensity regardless of blocking method. Blocking the arrays did not affect raw spot intensity, but affected background intensity on amine surfaces, BSA blocking being the lowest. Oligonucleotides and cDNA on unblocked GPS-modified slides gave the best signal (spot-to-background intensity ratio). Under the conditions evaluated, the unblocked GPS surface along with amine covalent coupling was the most appropriate for both cDNA and oligonucleotide microarrays.

DNA, Complementary↗

Dendrimeric coating of glass slides for sensitive DNA microarrays analysis.

Successful use and reliability of microarray technology is highly dependent on several factors, including surface chemistry parameters and accessibility of cDNA targets to the DNA probes fixed onto the surface. Here, we show that functionalisation of glass slides with homemade dendrimers allow production of more sensitive and reliable DNA microarrays. The dendrimers are nanometric structures of size-controlled diameter with aldehyde function at their periphery. Covalent attachment of these spherical reactive chemical structures on amino-silanised glass slides generates a reactive approximately 100 A layer onto which amino-modified DNA probes are covalently bound. This new grafting chemistry leads to the formation of uniform and homogenous spots. More over, probe concentration before spotting could be reduced from 0.2 to 0.02 mg/ml with PCR products and from 20 to 5 micro M with 70mer oligonucleotides without affecting signal intensities after hybridisation with Cy3- and Cy5-labelled targets. More interestingly, while the binding capacity of captured probes on dendrimer-activated glass surface (named dendrislides) is roughly similar to other functionalised glass slides from commercial sources, detection sensitivity was 2-fold higher than with other available DNA microarrays. This detection limit was estimated to 0.1 pM of cDNA targets. Altogether, these features make dendrimer-activated slides ideal for manufacturing cost-effective DNA arrays applicable for gene expression and detection of mutations.

DNA, Complementary↗