Search PubMed⌕ Search

PubMed · 12452097

Practice problems, adhesive solutions.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F J T Burke. 2002. Practice problems, adhesive solutions.. https://pubmed.ncbi.nlm.nih.gov/12452097/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Air classifier technology (ACT) in dry powder inhalation. Part 1. Introduction of a novel force distribution concept (FDC) explaining the performance of a basic air classifier on adhesive mixtures.

Air classifier technology (ACT) is introduced as part of formulation integrated dry powder inhaler development (FIDPI) to optimise the de-agglomeration of inhalation powders. Carrier retention and de-agglomeration results obtained with a basic classifier concept are discussed. The theoretical cut-off diameter for lactose of the classifier used, is between 35 and 15 microm for flow rates ranging from 20 to 70 l/min. Carrier retention of narrow size fractions is higher than 80% for flow rates between 30 and 60 l/min, inhalation times up to 6s and classifier payloads between 0 and 30mg. The de-agglomeration efficiency for adhesive mixtures, derived from carrier residue (CR) measurement, increases both with increasing flow rate and inhalation time. At 30 l/min, 60% fine particle detachment can be obtained within 3s circulation time, whereas at 60 l/min only 0.5s is necessary to release more than 70%. More detailed information of the change of detachment rate within the first 0.5s of inhalation is obtained from laser diffraction analysis (LDA) of the aerosol cloud. The experimental results can be explained with a novel force distribution concept (FDC) which is introduced to better understand the complex effects of mixing and inhalation parameters on the size distributions of adhesion and removal forces and their relevance to the de-agglomeration in the classifier.

Adhesives↗

Air classifier technology (ACT) in dry powder inhalation. Part 2. The effect of lactose carrier surface properties on the drug-to-carrier interaction in adhesive mixtures for inhalation.

The effect of carrier surface properties on drug particle detachment from carrier crystals during inhalation with a special test inhaler with basic air classifier has been studied for mixtures containing 0.4% budesonide. Carrier crystals were retained in the classifier during inhalation and subsequently examined for the amount of residual drug (carrier residue: CR). Carrier surface roughness and impurity were varied within the range of their appearance in standard grades of lactose (Pharmatose 80, 100, 110, 150 and 200M) by making special sieve fractions. It was found that roughness and impurity, both per unit calculated surface area (CSA), tend to increase with increasing mean fraction diameter for the carrier. Drug re-distribution experiments with two different carrier sieve fractions with distinct mean diameters showed that the amount of drug per CSA (drug load) in the state of equilibrium is highest for the coarsest fraction. This seems to confirm that surface carrier irregularities are places where drug particles preferentially accumulate. However, a substantial increase in surface roughness and impurity appears to be necessary to cause only a minor increase in CR at an inspiratory flow rate of 30 l/min through a classifier. At 60 l/min, CR is practically independent of the carrier surface properties. From the difference in CR between 30 and 60 l/min, it has been concluded that particularly the highest adhesive forces (for the largest drug particles) in the mixture are increased when coarser carrier fractions (with higher rugosity) are used. Not only increased surface roughness and impurities may be responsible for an increase in the adhesive forces between drug and carrier particles when coarser carrier fractions are used, but also bulk properties may play a role. With increasing mean carrier diameter, inertial and frictional forces during mixing are increased too, resulting in higher press-on forces with which the drug particles are attached to carrier crystals and to each other.

Adhesives↗