Search PubMed⌕ Search

PubMed · 12363291

Performance analysis.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Mike D Hughes, Roger M Bartlett. 2002. Performance analysis.. https://doi.org/10.1080/026404102320675594

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Load shift of the intervertebral disc after a vertebroplasty: a finite-element study.

Infiltrating osteoporotic cancellous bone with bone cement (vertebroplasty) is a novel surgical procedure to stabilize and prevent osteoporotic vertebral fractures. Short-term clinical and biomechanical results are encouraging; however, so far no reports on long-term results have been published. Our clinical observations suggest that vertebroplasty may induce subsequent fractures in the vertebrae adjacent to the ones augmented. At this point, there is only a limited understanding of what causes these fractures. We have previously hypothesized that adjacent fractures may result from a shift in stiffness and load following rigid augmentation. The purpose of this study is to determine the load shift in a lumbar motion segment following vertebroplasty. A finite-element (FE) model of a lumbar motion segment (L4-L5) was used to quantify and compare the pre- and post-augmentation stiffness and loading (load shift) of the intervertebral (IV) disc adjacent to the augmented vertebra in response to quasi-static compression. The results showed that the rigid cement augmentation underneath the endplates acted as an upright pillar that severely reduced the inward bulge of the endplates of the augmented vertebra. The bulge of the augmented endplate was reduced to 7% of its value before the augmentation, resulting in a stiffening of the IV joint by approximately 17%, and of the whole motion segment by approximately 11%. The IV pressure accordingly increased by approximately 19%, and the inward bulge of the endplate adjacent to the one augmented (L4 inferior) increased considerably, by approximately 17%. This increase of up to 17% in the inward bulge of the endplate adjacent to the one augmented may be the cause of the adjacent fractures.

Biomechanical Phenomena↗

Hidden complexity in the mechanical properties of titin.

Individual molecules of the giant protein titin span the A-bands and I-bands that make up striated muscle. The I-band region of titin is responsible for passive elasticity in such muscle, and contains tandem arrays of immunoglobulin domains. One such domain (I27) has been investigated extensively, using dynamic force spectroscopy and simulation. However, the relevance of these studies to the behaviour of the protein under physiological conditions was not established. Force studies reveal a lengthening of I27 without complete unfolding, forming a stable intermediate that has been suggested to be an important component of titin elasticity. To develop a more complete picture of the forced unfolding pathway, we use mutant titins--certain mutations allow the role of the partly unfolded intermediate to be investigated in more depth. Here we show that, under physiological forces, the partly unfolded intermediate does not contribute to mechanical strength. We also propose a unified forced unfolding model of all I27 analogues studied, and conclude that I27 can withstand higher forces in muscle than was predicted previously.

Biomechanical Phenomena↗