Laparoscopic linear cutting stapler failure.

Abstract

OBJECTIVES: To characterize the frequency and nature of problems with linear cutting staplers to help prevent complications in the future. These devices are often used during laparoscopic urologic procedures. METHODS: We retrospectively reviewed the experience with laparoscopic linear cutting staplers at two institutions routinely performing urologic laparoscopy and analyzed the difficulties with any staplers. Data from the Food and Drug Administration Center for Devices and Radiological Health were also examined to determine the prevalence and types of reported problems. RESULTS: In performing approximately 460 laparoscopic cases, we encountered 5 problems (1%) with endovascular gastrointestinal anastomosis staplers. Fifty-five additional cases in 50 patients were documented in the Food and Drug Administration database. Of the 55 patients, 15 (27%) required open conversion to manage the problem, 8 (15%) received blood transfusions, and 2 (4%) died postoperatively. Twenty-two events occurred during 19 laparoscopic donor nephrectomies (35%) without associated graft dysfunction, damage, or loss. All phases of instrument use were subject to problems; however, abnormal firing of the stapler and improper staple formation were the most common and morbid aspects of device malfunction. CONCLUSIONS: Despite the general reliability of linear cutting staplers, difficulties were encountered in every step of use. Most situations were successfully managed by prompt identification and appropriate intracorporeal maneuvers. Nevertheless, significant morbidity may occur, and conversion to an open operation should be considered. Many potential problems can be avoided by surgeon and staff education, and one should be aware of the alternative methods of tissue ligation currently available.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Donna Y Deng, Maxwell V Meng, Hiep T Nguyen, Gary C Bellman, Marshall L Stoller. 2002. Laparoscopic linear cutting stapler failure.. https://doi.org/10.1016/s0090-4295(02)01778-8

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Tip cooling effect and failure mechanism of field-emitting carbon nanotubes.

The cooling effect accompanying field electron emission has been considered for a single carbon nanotube (CNT) used as a field emission (FE) electron source. An improved model for the failure mechanism of field emitting CNTs has been proposed and validated. Our model predicts a maximum temperature (T-max) located at an interior point rather than the tip of the CNTs, and the failure of the CNT emitters tends to take place at the T-max point, inducing a segment by segment breakdown process. A combination of Joule heating and electrostatic force effect is proposed responsible for initiating the failure of the field emitting CNT and validated by in situ FE observation.

Equipment Failure↗

[Importance of an initial check-up for diagnostic radiology apparatus management].

The management of apparatus for diagnostic imaging is an important job for radiological technologists. In the last 10 years we have encountered 2227 malfunctions in 3652 days. We detected 163 cases at the initial check-up, which accounted for 7.3% of total cases. By performing an initial check-up, we detected one malfunction every 21 days and were able to keep the effects of mishaps to a minimum, prevent accidents, and obtain stable-quality images.

Equipment Failure↗