Search PubMed⌕ Search

PubMed · 12227852

Solid-phase extraction in clinical biochemistry.

Abstract

In order to measure low concentrations of analytes in plasma and urine, it is often necessary to extract and concentrate them. With solid-phase extraction (SPE), this is achieved by partitioning the analytes between a solid and a liquid or headspace vapour. A wide range of high-quality materials is now available to do this, offering a variety of separation modes for different applications. These include partitioning using reversed-phase, normal-phase, ion-exchange, restricted-access and immunoaffinity sorbents or molecularly imprinted polymers and, increasingly, combinations of these processes. Solid-phase microextraction was introduced to analyse volatile and semi-volatile compounds. The range of sampling formats has expanded from simple packed syringes to cartridges, disks, SPE pipette tips and 96-well plates. These developments have facilitated automated off- and on-line sample processing. The basic principles of SPE and the recent innovations are reviewed here. This is a technological growth area. Some of the developments are finding application in clinical toxicology. However, they could also be of wider value in clinical chemistry--for example, for analyses of volatile and non-volatile metabolites, peptides, radioactive elements and trace metal speciation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Valerie Walker, Graham A Mills. 2002. Solid-phase extraction in clinical biochemistry.. https://doi.org/10.1258/000456302320314476

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Three-dimensional porous nano-hydroxyapatite@gelatin composite as efficient adsorbent for uranyl ion removal from low-level radioactive wastewater.

The contamination of water resources by uranyl (UO22+) ions poses significant environmental and health risks, requiring the development of efficient and sustainable remediation strategies. Adsorption-based techniques have emerged as promising approaches in the field of UO22+ removal, but the design of cost-effective, high-capacity, and environmentally friendly adsorbents remains challenging. In this study, a three-dimensional porous nano-hydroxyapatite@gelatin (nHAP@Ge) composite was synthesized through glutaraldehyde cross-linking, combining the structural stability of Ge with the high uranium affinity of nHAP. The optimized nHAP@Ge, with a nHAP:Ge mass ratio of 1:0.5, exhibited exceptional UO22+ removal efficiency (97 %), along with high adsorption capacity (364.03 mg/g). Systematic characterizations using scanning electron microscopy (SEM), thermogravimetric analysis (TGA), Fourier transform infrared (FT-IR) spectroscopy, and X-ray photoelectron spectroscopy (XPS) methods revealed that the porous structure and surface functional groups (-OH, Ca2+, and PO43-) of the material synergistically contributed to binding UO22+ species. Furthermore, the incorporation of nHAP into the Ge framework resulted in enhanced thermal stability while significantly improving the UO22+ adsorption performance. This work presents a scalable, eco-friendly, and recyclable strategy for the effective treatment of uranium-contaminated water, with potential applications in nuclear wastewater treatment and environmental remediation.

Adsorption↗

Dual radiolabeling to study protein adsorption competition in relation with hemocompatibility.

Human fibrinogen (Fg) and albumin (HSA) were labeled with (3)H and (14)C, respectively. Dual counting allowed the adsorbed amount of the two proteins to be determined simultaneously. Single adsorption, adsorption of the two proteins in competition, but also exchange (substitution by molecules of the same nature) and displacement (desorption under the action of the other protein) experiments were performed on two model surfaces, glass and polystyrene (PS), as well as on pure polyvinylchloride (PVC-s) and on PVC from blood bag (PVC-b). As expected, the adsorbed amount of a single protein is higher on a hydrophobic compared to a hydrophilic surface. When the two proteins are adsorbed in competition, they are found in equal proportion on glass, while HSA is twice more abundant than Fg on PS and PVC-s and about six times more abundant on PVC-b. This trend is related to an increase of the water contact angle of the substrates. For PVC-b, the contact angle is affected by the presence of aliphatic components exposed at the extreme surface, as determined by angle-resolved X-ray photoelectron spectroscopy. In exchange and displacement experiments, the first adsorbed molecules remain dominating on PS while they can be removed from glass. Given the known importance of HSA and Fg adsorption for the fate of materials placed in contact with blood, the method described in this paper may be used as a first approach to orient the design of surfaces with improved hemocompatibility.

Adsorption↗

Effective immobilization of subunit protein in mesoporous silica modified with ethanol.

Ethoxylated FSM-type mesoporous silica (folded-sheet mesoporous material) with a pore diameter of 6.2 nm (FSM6.2) remarkably enhances rigidly of the structure in aqueous solutions. The esterified material could be used successfully as an adsorbent to accommodate subunit protein, methemoglobin (Fe(3+)). Furthermore, methemoglobin (Fe(3+)) in the pores of ethoxy-FSM is maintained a peroxidase activity similar to the native, indicating methemoglobin retains its fore subunit structure in the pores of FSM6.2.

Adsorption↗