Search PubMed⌕ Search

PubMed · 12209019

Comparison of different labeling methods for two-channel high-density microarray experiments.

Abstract

In this report we evaluate three methods for labeling nucleic acids to be hybridized to a cDNA microarray: direct labeling, indirect amino-allyl labeling, and the dendrimer labeling method (Genisphere). The dendrimer method requires the smallest quantity of sample, 2.5 microg of total RNA compared with 20 microg with the direct or indirect methods. Therefore, we wanted to know whether the performance of the dendrimer method is comparable to the other methods, or whether significant information is lost. Performance can be considered in terms of sensitivity, dynamic range, and reproducibility of the quantitative signals for gene intensity. We compared the three labeling methods by generating three sets of eight self-to-self hybridizations using the same total RNA sample in all cases ("replicate study"). In our analysis, we controlled for the effects of print-tip and background subtraction biases. We also performed a smaller study, namely, a dilution series study with five dilution points per labeling method, to evaluate one aspect of predictive ability. From the replicate study, the dendrimer method appeared to perform as well, and often better, with respect to reproducibility and ability to detect expression. However, in the dilution series study, this method was outperformed by the other two in terms of predictive ability and did not perform very well. These findings are helping to guide our decisions on what labeling method to use for subsequent studies, based on the purpose of a specific study and its limitations in terms of available material.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Elisabetta Manduchi, L Marie Scearce, John E Brestelli, Gregory R Grant, Klaus H Kaestner, Christian J Stoeckert. 2002-09-03. Comparison of different labeling methods for two-channel high-density microarray experiments.. https://doi.org/10.1152/physiolgenomics.00120.2001

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

IMPACT OF FLUORESCENT DYES ON MUTATIONS IN NEXT GENERATION SEQUENCING LIBRARY GENERATION.

DNA labelling fluorescent dyes such as ethidium bromide have long been considered to be highly mutagenic during DNA replication. While recent studies have pushed back on this narrative, the intercalative nature of these dyes continues to raise the possibility that these dyes can induce mutations. The iconPCR instrument by n6tec uses fluorescent dyes to measure amplification in real time and to adjust cycling conditions. However, since this use of qPCR is preparative and not analytical, mutations introduced by fluorescent dyes would be propagated into the sequencing reaction. To address the impact of these dyes on downstream analyses, we have performed routine mutation calling as well as mutational signature analysis on samples amplified using the iconPCR in the presence of either SYBR or EvaGreen. Sequence analysis revealed very minimal impacts of dyes on the reactions, largely within the noise regimen with only subtle changes in mutation rates seen. Mutational signature analysis was unable to identify any key signatures assignable to the dyes in either substitutions or indel domains. The mutational impact of intercalating dyes during fluorescence-guided amplification is therefore minimal and can be disregarded in all but the most sensitive NGS applications.

Fluorescent Dyes↗

Detecting oxygen consumption in the proximity of Saccharomyces cerevisiae cells using self-assembled fluorescent nanosensors.

We describe a strategy for the preparation and self-assembly of fluorescent nanosensors onto Saccharomyces cerevisiae cell surfaces for dynamically measuring oxygen concentration in the proximity of living cells. Amine functionalized polystyrene nanobeads were impregnated with an oxygen-sensitive ruthenium(II) complex and the beads' surface was coated with polyethylenimine. The resulting nanosensors were assembled on individual S. cerevisiae cells in a controlled manner at physiological pH for continuously monitoring oxygen consumption. This approach exemplifies a general scheme for assembling fluorescent nanosensors on cells for the non-invasive, reversible, and real-time measurement of other physiologically relevant processes, such as the efflux of protons and carbon dioxide, or the influx of glucose.

Fluorescent Dyes↗

Metal-based turn-on fluorescent probes for sensing nitric oxide.

Nitric oxide, a reactive free radical, regulates a variety of biological processes. The absence of tools to detect NO directly, rapidly, specifically, and selectively motivated us to synthesize metal-based fluorescent probes to visualize the presence of NO. We prepared and investigated Co(II), Fe(II), Ru(II), Rh(II), and Cu(II) complexes as turn-on fluorescent NO sensors. Our exploration has provided insight into how the interaction of transition-metal centers with nitric oxide can be utilized for NO sensing.