Search PubMed⌕ Search

PubMed · 12201410

Material-specific analysis using coherent-scatter imaging.

Abstract

Coherent-scatter computed tomography (CSCT) is a novel imaging method we are developing to produce cross-sectional images based on the low-angle (<10 degrees) scatter properties of tissue. At diagnostic energies, this scatter is primarily coherent with properties dependent upon the molecular structure of the scatterer. This facilitates the production of material-specific maps of each component in a conglomerate. Our particular goal is to obtain quantitative maps of bone-mineral content. A diagnostic x-ray source and image intensifier are used to acquire scatter patterns under first-generation CT geometry. An accurate measurement of the scatter patterns is necessary to correctly identify and quantify tissue composition. This requires corrections for exposure fluctuations, temporal lag in the intensifier, and self-attenuation within the specimen. The effect of lag is corrected using an approximate convolution method. Self-attenuation causes a cupping artifact in the CSCT images and is corrected using measurements of the transmitted primary beam. An accurate correction is required for reliable density measurements from material-specific images. The correction is shown to introduce negligible noise to the images and a theoretical expression for CSCT image SNR is confirmed by experiment. With these corrections, the scatter intensity is proportional to the number of scattering centers interrogated and quantitative measurements of each material (in g/cm3) are obtained. Results are demonstrated using both a series of poly(methyl methacrylate) (PMMA) sheets of increasing thickness (2-12 mm) and a series of 5 acrylic rods containing varying amounts of hydroxyapatite (0-0.400 g/cm3), simulating the physiological range of bone-mineral density (BMD) found in trabecular bone. The excellent agreement between known and measured BMD demonstrates the viability of CSCT as a tool for densitometry.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Deidre L Batchelar, Ian A Cunningham. 2002. Material-specific analysis using coherent-scatter imaging.. https://doi.org/10.1118/1.1493216

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of micromechanical stimulations on osteoblasts: development of a device simulating the mechanical situation at the bone-implant interface.

Many experimental models have been developed to investigate the effects of mechanical stimulation of cells, but none of the existing devices can simulate micromotions at the cellular-mechanical interface with varying amplitudes and loads. Osteoblasts are sensitive to mechanical stimuli, so to study the bone-implant interface it would be important to quantify their reaction in a situation mimicking the mechanical situation arising at that interface. In this study, we present the development of a new device allowing the application of micromotions and load on cells in vitro. The new device allowed the cells to be stimulated with sinusoidal motions of amplitudes comprised between +/- 5 and +/- 50 microm, frequencies between 0.5 and 2 Hz, and loads between 50 and 1000 Pa. The device, with a total length of 20 cm, was designed to work in an incubator at 37 degrees C and 100% humidity. Expression of various bone important genes was monitored by real-time RT-PCR. Micromotions and load were shown to affect the behavior of osteoblasts by down-regulating the expression of genes necessary for the creation of organic extracellular matrix (collagen type I) as well as for genes involved in the mineralization process (osteocalcin, osteonectin). The developed device could then be used to simulate different mechanical situations at the bone-implant interface.

Bone and Bones↗

Prosthetic particles modify the expression of bone-related proteins by human osteoblastic cells in vitro.

Loss of bone near joint prostheses is thought to be caused by activation of recruited osteoclasts by osteolytic mediators induced by wear particles. It is proposed that particles inhibit osteogenesis during bone remodelling causing a reduction in the levels of peri-implant bone. This study explores whether prosthetic particles modulate bone formation by affecting osteoblastic bone-related mRNAs (alkaline phosphatase, pro-collagen Ialpha1, osteopontin, osteonectin, osteocalcin, bone sialoprotein and thrombospondin) or their translated proteins using titanium alloy, commercially pure titanium, and cobalt-chrome particles. The direct effect of the particles revealed no change to the expression of the bone-related mRNAs in human bone-derived cells (HBDC) at the time points investigated; although non-collagenous translated proteins expressed by these HBDC were significantly effected (p<0.05). Different patterns of expression for bone-related proteins were induced by the different particles both directly and indirectly. Inflammatory mediators (interleukin-1beta, tumor necrosis factor alpha, interleukin-6, and prostaglandin E2) had similar effects on HBDC to the media obtained from monocytes incubated with particles. This study shows that prosthetic wear particles can significantly modify the expression of bone-related proteins by osteogenic cells in vitro. These alterations in osteogenic activity at the interface of the implant and bone may be an important factor in the failure of many orthopaedic implants.

Bone and Bones↗