Search PubMed⌕ Search

PubMed · 12198436

Hydroxyapatite.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Robert J Havlik, PSEF DATA Committee. 2002-09-15. Hydroxyapatite.. https://doi.org/10.1097/01.prs.0000020998.55126.10

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Comparative study of bone cements prepared with either HA or alpha-TCP and functionalized methacrylates.

The properties of bone cements prepared with both hydroxyapatite (HA) and alpha-tricalcium phosphate (alpha-TCP) and methacrylates containing acidic or basic groups are the main interest of this article. The presence of methacrylic acid or diethyl amino ethyl methacrylate as comonomers in the bone cement and both ceramic types as filler were found not to affect the amount of residual monomer, which was generally less than 4.5 wt%. In contrast, setting times, maximum temperature, and glass transition temperature were found to be composition dependent. For samples with acidic comonomer, a faster setting time, a higher maximum temperature, and higher glass transition temperatures were observed compared to those with the basic comonomer. The presence of the fillers slightly increased the setting time but did not affect the other parameters. The mechanical properties of the filled bone cements depended mainly on composition and type of testing. Both HA or alpha-TCP filled systems fulfilled the minimum compressive strength required for bone cement application, although a significantly lower value was observed for the alkaline comonomer systems. The minimum bending strength was not satisfied by any of these formulations. The tensile and shear strength of these composites ranged from 20 to 37.9 and from 18 to 27 MPa, respectively. In all cases it was higher for bone cements containing methacrylic acid. The results of this study suggest that the properties of dry unfilled bone cements prepared with MAA are comparable to CMW 3 in mechanical terms but inferior in their setting properties.

Bone Cements↗

Hydroxyapatite cement scaffolds with controlled macroporosity: fabrication protocol and mechanical properties.

Precipitated hydroxyapatite cement scaffolds with macroporosity of controlled size and shape were successfully built using a solid freeform fabrication process. The negative macroporosity was designed using CAD software and built with an inkjet machine. A slip casting process using a plaster mold was used to precipitate the cement and manufacture samples for mechanical testing. The negative macroporosity was then extracted from the samples using a thermal process. Compression, tension and torsion tests were completed successfully on the precipitated hydroxyapatite cement samples in moist condition. Elastic and strength properties were measured for these three loading cases and compared to the plain hydroxyapatite cement properties reported in a previous study. Homogenization theory was applied to estimate the elastic properties of the manufactured scaffolds. A good correlation was obtained between the experimental data and the theory.

Bone Cements↗

Shrinkage stresses in bone cement.

Shrinkage of bone cement is reported primarily as a consequence of polymerisation, however thermal shrinkage also occurs as a result of its exothermic reaction. It is proposed that the latter effect is important, since it occurs late in the curing cycle at a time when the cement has attained its mechanical properties as a solid, and that residual stresses result. Observations from experiments and literature reports suggest that residual stresses may be sufficient to initiate cracks at the interface between hip replacement stems and cement.A theoretical model has been developed to calculate interference stresses, using thick-walled cylinder theory, on the basis of thermal and total shrinkages. Thermal shrinkage values were calculated using the coefficient of linear thermal expansion of bone cement, while total shrinkages were measured. Moduli of elasticity values were measured for acrylic bone cements ranging from 2.1 to 2.7GPa, as were Poisson's ratio values ranging from 0.38 to 0.46. Theoretical calculation of stresses in a cement mantle, based on assumptions of thermal shrinkage alone, predicted circumferential stresses of 8.4-25.2MPa for cement curing temperatures in the range 60-140 degrees C. It is concluded that cracks observed around hip prosthesis stems in laboratory specimens of bone cement are due to shrinkage and that residual stresses are sufficient to cause crack initiation prior to functional loading.

Bone Cements↗