A new parametric method based on S-distributions for computing receiver operating characteristic curves for continuous diagnostic tests.

Abstract

Receiver operating characteristic (ROC) curves provides a method for evaluating the performance of a diagnostic test. These curves represent the true positive ratio, that is, the true positives among those affected by the disease, as a function of the false positive ratio, that is, the false positives among the healthy, corresponding to each possible value of the diagnostic variable. When the diagnostic variable is continuous, the corresponding ROC curve is also continuous. However, estimation of such curve through the analysis of sample data yields a step-line, unless some assumption is made on the underlying distribution of the considered variable. Since the actual distribution of the diagnostic test is seldom known, it is difficult to select an appropriate distribution for practical use. Data transformation may offer a solution but also may introduce a distortion on the evaluation of the diagnostic test. In this paper we show that the distribution family known as the S-distribution can be used to solve this problem. The S-distribution is defined as a differential equation in which the dependent variable is the cumulative. This special form provides a highly flexible family of distributions that can be used as models for unknown distributions. It has been shown that classical statistical distributions can be represented accurately as S-distributions and that they occur in a definite subspace of the parameter space corresponding to the whole S-distribution family. Consequently, many other distributional forms that do not correspond to known distributions are provided by the S-distribution. This property can be used to model observed data for unknown distributions and is very useful in constructing parametric ROC curves in those cases. After fitting an S-distribution to the observed samples of diseased and healthy populations, ROC curve computation is straightforward. A ROC curve can be considered as the solution of a differential equation in which the dependent variable is the ratio of true positives and the independent variable is the ratio of false positives. This equation can be easily obtained from the S-distributions fitted to observed data. Using these results, we can compute pointwise confidence bands for the ROC curve and the corresponding area under the curve. We shall compare this approach with the empirical and the binormal methods for estimating a ROC curve to show that the S-distribution based method is a useful parametric procedure.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Albert Sorribas, Jaume March, Javier Trujillano. 2002-05-15. A new parametric method based on S-distributions for computing receiver operating characteristic curves for continuous diagnostic tests.. https://doi.org/10.1002/sim.1086

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Smooth semiparametric receiver operating characteristic curves for continuous diagnostic tests.

We propose a semiparametric kernel distribution function estimator, based on which a new smooth semiparametric estimator of the receiver operating characteristic (ROC) curve is constructed. We derive the asymptotic bias and variance of the newly proposed distribution function estimator and show that it is more efficient than the traditional non-parametric kernel distribution estimator. We also derive the asymptotic bias and variance of our new ROC curve estimator and show that it is more efficient than the smooth non-parametric ROC curve estimator proposed by Zou et al. (Stat. Med. 1997; 16:2143-2156) and Lloyd (J. Am. Stat. Assoc. 1998; 93:1356-1364). For our proposed estimators, we derive data-based methods for bandwidth selection. In addition, we present some results on the analysis of two real data sets. Finally, a simulation study is presented to show that our estimators are better than the non-parametric counterparts in terms of bias, standard error, and mean-square error.

Area Under Curve↗

Redox potential measurement as a rapid method for microbiological testing and its validation for coliform determination.

The redox potential is one of the most complex indicators of the physiological state of microbial cultures and its measurement could be a useful tool for the qualitative and quantitative determination of the microbial contamination. During the bacterial growth, the redox potential of the medium decreases. The shape of the redox potential curve is characteristic on the type of microorganism, and the rate of the change (dE/dt) is proportional to the living cell concentration. Defining the time required to reach a significant change in redox potential as Time to Detection (TTD), similarly to the impedimetric measurements, a strict linear correlation could be established between the TTD and the logarithm of the initial concentration of microorganisms. On the base of this calibration curve, the determination of living cell concentration could be simplified. For the experiments, a computer-controlled multi-channel measuring system and software was developed by the authors. The redox potential measurement method was tested and validated for the determination of coliform bacteria. The results have proved the high efficiency and reliability of the new method.

Area Under Curve↗

Determination of N-methyl-4-isoleucine-cyclosporin (NIM811) in human whole blood by high performance liquid chromatography-tandem mass spectrometry.

A liquid chromatographic method with tandem mass spectrometric detection (LC-MS/MS) for the determination of N-methyl-4-isoleucine-cyclosporin (NIM811) was developed and validated over the concentration range 1-2500 ng/mL in human whole blood using a 0.05 mL sample volume. NIM811 and the internal standard, d(12)-cyclosporin A (d(12)-CsA), were extracted from blood using MTBE via liquid-liquid extraction. After evaporation of the organic solvent and reconstitution, a 10 microL aliquot of the resulting extract was injected onto the LC-MS/MS system. Chromatographic separation of NIM811 and internal standard was performed using a Waters Symmetry RP-8 (50 x 4.6 mm, 3 microm particle size) column. The mobile phase consists of 10 mm ammonium acetate in water (A) and acetonitrile (B), with 45% B from 0 to 0.2 min, 45 to 85% B from 0.2 to 0.8 min and 85% B from 0.8 to 2.2 min. The total run time was 3.5 min with a flow rate of 0.8 mL/min. The method was validated for sensitivity, linearity, reproducibility, stability, dilution integrity and recovery. The precision and accuracy of quality control samples at low (2.00 ng/mL), medium (20.0 and 400 ng/mL) and high (2000 ng/mL) concentrations were in the range 1.1-4.3% relative standard deviation (RSD) and -2.5-10.0% (bias), respectively, from three validation runs. The method has been used to measure the exposure of NIM811 in human subjects.

Area Under Curve↗