Search PubMed⌕ Search

PubMed · 12051224

Bladder catheterisation.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Roger Feneley, Danny Painter, Ann Evans, David Stickler. 2002. Bladder catheterisation.. https://pubmed.ncbi.nlm.nih.gov/12051224/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Influence of high-energy photon beam irradiation on pacemaker operation.

In this paper, we determine the influence of high-energy photon beam irradiation used for external radiotherapy on pacemakers, at different doses and dose rates. Ninety-six pacemakers of various origins and ages underwent in vitro high-energy photon irradiation under technical conditions close to external radiotherapy, using a linear accelerator delivering photons of high energy (18 MV). Various dose levels (up to 200 Gy for certain particularly resistant pacemakers) were delivered to pacemakers located in a water-equivalent phantom with several dose rates (from 0.05 to 8 Gy min(-1)). Observed failures were sorted into eight classes of progressive harmfulness, some of them possibly lethal. One irradiated pacemaker exhibited an important defect at a dose rate of 0.2 Gy min(-1), for a cumulative dose of 0.15 Gy. Two pacemakers showed an important defect at a cumulative dose of 1 Gy, while nine pacemakers failed at a cumulative dose lower than or equal to 2 Gy and 13 failed at a cumulative dose lower than or equal to 5 Gy. The most important failure probability (70% of irradiated pacemakers) is observed for 8 Gy min(-1), whereas no pacemakers failed at a dose rate lower than or equal to 0.2 Gy min(-1). In conclusion, warnings given by manufacturers about the maximum tolerable cumulative radiation doses for safe operation of irradiated pacemakers (5 Gy), even reduced to 2 Gy, are not reliable. The spread of cumulative doses inducing failures is very large since our observations show an important failure at 0.15 Gy, while ten pacemakers withstood more than 140 Gy of cumulative dose. The safe operation of pacemakers under irradiation depends mainly on type and model. It depends also on dose rate. From our observations, for the safe operation of pacemakers, a recommendation of a maximum dose rate of 0.2 Gy min(-1) rejecting direct irradiation of the pacemaker at a standard dose rate for tumour treatment (2 Gy min(-1)) is made.

Equipment Failure↗

PACS disaster recovery procedures--evaluation in a clinical environment.

Failures of picture archiving communication systems are not a common event and are even less commonly documented. Planning in advance for such an event can have an enormous effect on the overall impact on clinical operations. This report provides insight into the planning required for disaster recovery and how the impact on clinical operations can be minimized if this planning takes place in advance.

Equipment Failure↗

A wake-up call.

Explore the source record for details and available documents.

Equipment Failure↗