Search PubMed⌕ Search

PubMed · 12047792

Interventions for aortic coarctation.

Abstract

The standard treatment of coarctation of the aorta is surgical. In the last 2 decades, however, treatment by catheter intervention has become more widespread, using either balloon angioplasty or primary stent implantation. Balloon angioplasty was originally used for recurrent coarctation after surgical repair but has now been shown equally effective for unoperated coarctation. The procedure produces a satisfactory gradient reduction in approximately 80% of patients, with transverse arch hypoplasia the main predictor of poorer outcome. Rates of restenosis and aneurysm formation are less than 10%. Primary stent implantation has been suggested as an option potentially superior to angioplasty alone. Stent implantation limits elastic recoil and potentially reduces aneurysm formation by reducing the amount of balloon stretch required. The incidence of suboptimal gradient reduction is low, probably 5% or less, as is the rate of restenosis. Aneurysm formation, vascular complications, and stent migration also occur in less than 5%. Catheter interventions are now an established treatment strategy for coarctation, with a good success rate and safety profile. The outcome for native and recurrent coarctation appears similar. The authors believe that for most adult patients with coarctation of the aorta, catheter intervention should be offered as initial therapy.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T S Hornung, L N Benson, P R McLaughlin. Interventions for aortic coarctation.. https://doi.org/10.1097/00045415-200205000-00002

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Temporal evolution of gene expression in rat carotid artery following balloon angioplasty.

The success of vascular intervention including angioplasty, stenting, and arterial bypass remains limited by negative remodeling resulted in lumen restenosis. This study was to characterize the global transcription profile reflecting concurrent events along arterial remodeling and neointima formation in a rat carotid artery balloon-injury model. Expression profiling of injured and control common carotid arteries on days 4, 7, 14 post-injury that mark the major pathohistological progression stages of neointimal formation were recorded on high-density oligonucleotide arrays. A subset of genes from microarray-based data was further studied using quantitative real time RT-PCR and in situ hybridization with sequential arterial samples from days 1 to 28 post-injury. The gene-encoded proteins were validated with Western blot. Besides temporal induction of a large cluster of genes over-represented by cell proliferation and macromolecule metabolism gene ontology categories, a fast-evolving inflammation could be demonstrated by the induction of Tgfb and other anti-inflammatory genes (e.g., C1qtnf3 (C1q and tumor necrosis factor related protein 3 (predicted))) and a shift from type 1 to 2 helper T cell response. The most significant signature of the induced neointimal profile is enrichment of genes functionally related to angiogenesis and extracellular matrix (ECM) remodeling (e.g., Spp1 (secreted phosphoprotein 1), CD44 (CD44 antigen), and Cxcl12 (chemokine (C-X-C motif) ligand 12 (stromal cell-derived factor 1)). Some of the genes represent stress-responsive mesenchymal stromal cell cytokines. This study highlighted mesenchymal stromal cell cytokines-driven inflammatory extracellular matrix remodeling, as target processes for potential clinical therapeutic intervention.

Angioplasty, Balloon↗

Hepatic artery stenosis after liver transplant, managed with percutaneous angioplasty and stent placement.

Hepatic artery stenosis is a recognized vascular complication of orthotopic liver transplant that carries significant morbidity and mortality. The authors present a case of hepatic artery stenosis in a 50-year-old female successfully treated with balloon angioplasty and stent. This case report highlights the importance of percutaneous intervention as a preferred treatment option in patients with hepatic artery stenosis post-orthotopic liver transplant.

Angioplasty, Balloon↗

Increased in-stent stenosis in ApoE knockout mice: insights from a novel mouse model of balloon angioplasty and stenting.

OBJECTIVE: We aimed to develop and validate a model of angioplasty and stenting in mice that would allow investigation of the response to stent injury using genetically modified mouse strains. METHODS AND RESULTS: Aortic segments from either C57BL/6 wild-type or atherosclerotic ApoE-KO mice underwent balloon angioplasty alone or balloon angioplasty and stenting with a 1.25x2.5 mm stainless steel stent. Vessels were carotid-interposition grafted into genetically identical littermate recipients and harvested at 1, 7, 14, or 28 days. In wild-type mice, stenting generated an inflammatory vascular injury response between days 1 to 7, leading to the development of neointimal hyperplasia by day 14, which further increased in area by day 28 leading to the development of in-stent stenosis. Uninjured vessels and vessels injured by balloon angioplasty alone developed minimal neointimal hyperplasia. In stented ApoE-KO mice, neointimal area at 28 days was 30% greater compared with wild-type mice. CONCLUSIONS: By reproducing important features of human stenting in atherosclerotic mice, we provide the potential to investigate molecular pathways and evaluate novel therapeutic targets for stent injury and restenosis.

Angioplasty, Balloon↗