Search PubMed⌕ Search

PubMed · 12014889

Preterm birth and visual development.

Abstract

Visual impairment, oculomotor abnormalities, and refractive error are prevalent among children with a history of preterm birth. These conditions may result from exposure of the immature visual system to early visual stimulation, from nutritional deficits that occur following the abrupt loss of placental maternal-to-fetal transfer of essential nutrients, and as secondary effects of systemic disease or complications associated with preterm birth. This chapter provides an overview of the structural and functional maturation of the visual system of the healthy preterm infant and of several forms of visual impairment that are prevalent in the low birth weight population.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E E Birch, A R O'Connor. 2001. Preterm birth and visual development.. https://doi.org/10.1053/siny.2001.0077

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Reproducibility of multifocal ERG using the scanning laser ophthalmoscope.

BACKGROUND: Prior to application of multifocal electroretinography (mfERG) using the scanning laser ophthalmoscope (SLO) in a clinical routine setting it is important to determine the reproducibility of this technique in normals during the use of monochromatic red HeNe laser light. METHODS: Thirty-five eyes of 35 volunteers (visual acuity > or =0.8) were examined using the SLO for mfERG with two test patterns in a 20-deg diameter field. Multifocal ERG was performed using the RETIscan system with a binary m-sequence technique. Evaluation was performed for the first-order kernel concentric ring segments. Three measurements were performed for each type of sequence (six sequences for seven hexagons, eight for 19 hexagons) with removal of electrodes between the recordings. Stimulus intensity for all subjects was set to 235 cd/m2 (background illumination 20 cd/m2). We used gold-foil electrodes to obtain good signal quality while not disturbing corneal transmission and refraction. RESULTS: The coefficient of variation for the P1 amplitudes for the center and surrounding ring(s) was 10.4% and 9.3% for seven hexagons and 15.2%, 9.3% and 7.6%, for 19 hexagons, respectively. The corresponding intraclass correlation coefficients varied between 0.59 and 0.77. The CV for the P1 peak times varied between 1.3% and 1.5% for ring analysis in seven and 19 hexagons. CONCLUSION: Our data shows that the setup of mfERG with the SLO provides a retest variability comparable with conventional CRT examinations. One advantage is the simultaneous visualization of the fundus with observation of fixation during examination, thereby allowing more confidence in pathological results.

Electroretinography↗

Multifocal electroretinography response after laser photocoagulation of a subretinal nematode.

PURPOSE: To describe multifocal electroretinography findings before and after laser photocoagulation of a subretinal nematode in diffuse unilateral subacute neuroretinitis. METHOD: Observational case report. A 45-year-old woman with left eye inflammation, subretinal tracts superior and temporal to the fovea, and a subretinal coiled mobile parasite was treated with laser photocoagulation to destroy the nematode. Multifocal electroretinography was performed before and after laser photocoagulation. RESULTS: In the left eye, multifocal electroretinography before treatment showed decreased foveal response density and increased parafoveal and perifoveal waveform amplitudes. Two months after laser photocoagulation, multifocal electroretinography showed full recovery of normal findings and the visual acuity remained 20/20. CONCLUSION: Multifocal electroretinography appears to be useful in evaluating the retinal findings after photocoagulation of a parasite associated with diffuse unilateral subacute neuroretinitis.

Electroretinography↗