Search PubMed⌕ Search

PubMed · 1198395

Variability of routine pulmonary function tests.

Abstract

Pulmonary function tests sometimes indicate a progressive deterioration and at other times a 'stepwise' worsening which may be followed by improvement. Interpretation depends on the extent of random or diurnal variations in function. Routing pulmonary function tests (VC, FEV1, FRC, and airway resistance (Raw)) were repeatedly measured in normal subjects, patients with stable irreversible airways obstruction, and patients with stable restrictive disease. In all groups there was a significant (P less than 0.001) diurnal variation in Raw, with high values in the morning, low values at noon, and rising values in the evening. The midday Raw values were about 80% of the highest daily values. The considerable random and diurnal variability seen in all tests is reflected in the range of high and low values (% of mean individual response) in individuals. The largest variation in an individual between measurements taken at two different times was 81% in Raw (range: 40% above to 41% below the mean). There was less variation in FEV1 (29%), FRC (62%), and VC (30%). Thus the finding of a stepwise change in function could reflect its natrual variability. When repeated studies are done to assess progress or the effects of therapy on disease, there are many factors, including the time of day at which the tests are performed, which should be standardized as far as possible.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Hruby, J Butler. 1975. Variability of routine pulmonary function tests.. https://doi.org/10.1136/thx.30.5.548

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

An integrated multiscale air quality modelling framework for industrial park pollution: Linking local emissions to regional transport.

Capturing the spatiotemporal distribution of pollutants in industrial parks remains challenging for regional air quality models because of their coarse resolution (3 km), resulting in uncertainties in local emission quantification. To address this, we developed the Integrated Multiscale Air Quality Modelling System for Industry (IAQMS-Industry), coupling the regional Nested Air Quality Prediction Modelling System (NAQPMS) with a city-scale chemical transport model. This framework integrates point-source locations and Gaussian plume dispersion to simulate particulate matter with a diameter smaller than 2.5 micrometres (PM2.5) at 100 m resolution. Applied to the Beijing Yi Zhuang and Tangshan industrial parks and evaluated against observations. The coupled model achieved a normalized mean bias (NMB) ranging from 3.1 % to 6.2 %, improving upon NAQPMS (-16.9 % to -7.7 %). Spatial analysis revealed that coarse regional grids underestimated the PM2.5​ concentrations at industrial sites by smoothing gradients, whereas IAQMS-Industry successfully resolved spatial patterns. Industrial point emissions accounted for 22.9 %-26.4 % of PM2.5 in the coupled model, which was significantly greater than the regional model estimates of 1.6 %-13.7 %. These findings indicate that regional models overestimate pollutant dispersion processes in industrial parks while underestimating local industrial impacts. By explicitly resolving point-source dynamics and linking them to regional transport, IAQMS-Industry provides a robust tool for designing targeted emission controls in industrial cities and balancing local air quality improvements with minimized regional pollution outflow. This study underscores the necessity of multiscale modelling for accurate source apportionment and informed environmental governance in industrial zones.

Air Pollution↗

Meteorological variables connected with airborne ragweed pollen in Southern Hungary.

About 30% of the Hungarian population has some type of allergy, 65% of them have pollen sensitivity, and at least 60% of this pollen sensitivity is caused by ragweed. The short (or common) ragweed (Ambrosia artemisiifolia = Ambrosia elatior) has the most aggressive pollen of all. Clinical investigations prove that its allergenic pollen is the main reason for the most massive, most serious and most long-lasting pollinosis. The air in the Carpathian Basin is the most polluted with ragweed pollen in Europe. The aim of the study is to analyse how ragweed pollen concentration is influenced by meteorological elements in a medium-sized city, Szeged, Southern Hungary. The data basis consists of daily ragweed pollen counts and averages of 11 meteorological parameters for the 5-year daily data set, between 1997 and 2001. The study considers some of the ragweed pollen characteristics for Szeged. Application of the Makra test indicates the same period for the highest pollen concentration as that established by the main pollination period. After performing factor analysis for the daily ragweed pollen counts and the 11 meteorological variables examined, four factors were retained that explain 84.4% of the total variance of the original 12 variables. Assessment of the daily pollen number was performed by multiple regression analysis and results based on deseasonalised and original data were compared.

Air Pollution↗