Search PubMed⌕ Search

PubMed · 11919284

When does the incongruence length difference test fail?

Abstract

This paper examines the efficiency of the incongruence length difference test (ILD) proposed by Farris et al. (1994) for assessing the incongruence between sets of characters. DNA sequences were simulated under various evolutionary conditions: (1) following symmetric or asymmetric trees, (2) with various mutation rates, (3) with constant or variable evolutionary rates along the branches, and (4) with different among-site substitution rates. We first compared two sets of sequences generated along the same tree and under the same evolutionary conditions. The probability of a Type-I error (wrongly rejecting the true hypothesis of congruence) was substantially below the standard 5% level of significance given by the ILD test; this finding indicates that the choice of the 5% level is rather conservative in this case. We then compared two data sets, still generated along the same tree, but under different evolutionary conditions (constant vs. variable evolutionary rate, homogeneity vs. heterogeneity rate of substitution). Under these conditions, the probability of rejecting the true hypothesis of congruence was greater than the 5% given by the ILD test and increased with the number of sites and the degree to which the tree was asymmetric. Finally, the comparison of the two data sets, simulated under contrasting tree structures (symmetric vs. asymmetric) but under the same evolutionary conditions, led us to reject the hypothesis of congruence, albeit weakly, particularly when the number of informative sites was low and among-site substitution rate heterogeneous. We conclude that the ILD test has only limited power to detect incongruence caused by differences in the evolutionary conditions or in the tree topology, except when numerous characters are present and the substitution rate is homogeneous from site to site.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Pierre Darlu, Guillaume Lecointre. 2002. When does the incongruence length difference test fail?. https://doi.org/10.1093/oxfordjournals.molbev.a004098

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗