Search PubMedSearch

PubMed · 1186323

An online sampled-data waveform control system.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E L Le Page, B M Johnstone. 1975. An online sampled-data waveform control system.. https://doi.org/10.1007/bf02477319

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Treatable domain and optimal frequency for brain tumors during ultrasound hyperthermia.

PURPOSE: To examine the optimal ultrasound frequency and the treatable domain determined by the tumor size and tumor depth when an external ultrasound heating system is employed for the brain tumor hyperthermia. METHODS AND MATERIALS: This work employs a simplified model of a scanned ultrasound transducer power deposition (a cone with convergent/divergent shape) and a search algorithm to investigate the optimal frequency and the treatable domain. The distributions of temperature and SAR (specific absorption rate) ratio are used to determine the appropriateness of the acoustic window size and the input power level for a yielded set of tumor conditions. The factors considered are the acoustic window size, tumor size and depth, ultrasound frequency, and the acoustic absorption of the post-target bone behind the tumor. RESULTS: Simulation results demonstrate that the optimal frequency depends on the tumor depth and the acoustic absorption of the post-target bone. However, it is almost independent of the acoustic window size. The optimal frequency shifts to a higher level for a deeper tumor heating to reduce the effect of the high acoustic absorption of post-target bone. Moreover, the treatable domain is proportional to the acoustic window size and related to the ultrasound frequency. CONCLUSION: It may not be possible to deliver appropriate ultrasonic energy to heat a brain tumor without overheating the normal brain tissue and/or the post-target bone under the constraints of the available acoustic window size for the ultrasonic beam, ultrasonic attenuation of brain tissue, high absorption of post-target bone, and high blood perfusion rate. The results of this study can be a guideline for designing an optimal ultrasound heating system, arranging the transducers, and implementing further treatment planning for the brain tumor hyperthermia.

Acoustics

Comparison of NIOSH noise criteria and OSHA hearing conservation criteria.

BACKGROUND: This study was conducted to compare noise exposure measurements based on the recently revised noise exposure criteria recommended by the U.S. National Institute for Occupational Safety and Health (NIOSH) and the current U.S. Occupational Safety and Health Administration (OSHA) Hearing Conservation Amendment to the occupational noise standard. METHODS: Daily 8-hour time-weighted average (TWA) personal noise exposures were obtained for 61 workers using dosimeters set simultaneously to the NIOSH and OSHA Hearing Conservation Amendment (OSHA-HCA) criteria. A variety of work groups with the potential for noise exposure were evaluated as a part of this investigation. RESULTS: Noise dose based on the NIOSH criteria was higher than the corresponding OSHA-HCA noise dose with differences in noise exposures measured under the two criteria equal to 6.6 dBA. Should the new NIOSH recommendation on noise measurement be adopted as standard, the number of workers to be enrolled in a hearing loss prevention program was estimated to increase by 2. 7-fold from 23% to 75% of the study population. CONCLUSIONS: The results of this study indicate that if the NIOSH criteria are to be adopted as an OSHA standard, there is likely to be a substantial increase in the number of workers in hearing conservation programs.

Acoustics