Search PubMed⌕ Search

PubMed · 11834817

Third-generation biomedical materials.

Abstract

Whereas second-generation biomaterials were designed to be either resorbable or bioactive, the next generation of biomaterials is combining these two properties, with the aim of developing materials that, once implanted, will help the body heal itself.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Larry L Hench, Julia M Polak. 2002-02-08. Third-generation biomedical materials.. https://doi.org/10.1126/science.1067404

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

First evidence that bone marrow cells contribute to the construction of tissue-engineered vascular autografts in vivo.

BACKGROUND: Materials commonly used to repair complex cardiac defects lack growth potential and have other unwanted side effects. We designed and tested a bone marrow cell (BMC)-seeded biodegradable scaffold that avoids these problems. METHODS AND RESULTS: To demonstrate the contribution of the BMCs to histogenesis, we labeled them with green fluorescence, seeded them onto scaffolds, and implanted them in the inferior vena cava of dogs. The implanted grafts were analyzed immunohistochemically at 3 hours and subsequently at 2, 4, and 8 weeks after implantation using antibodies against endothelial cell lineage markers, endothelium, and smooth muscle cells. There was no stenosis or obstruction caused by the tissue-engineered vascular autografts (TEVAs) implanted into the dogs. Immunohistochemically, the seeded BMCs expressing endothelial cell lineage markers, such as CD34, CD31, Flk-1, and Tie-2, adhered to the scaffold. This was followed by proliferation and differentiation, resulting in expression of endothelial cells markers, such as CD146, factor VIII, and CD31, and smooth muscle cell markers, such as alpha-smooth muscle cell actin, SMemb, SM1, and SM2. Vascular endothelial growth factor and angiopoietin-1 were also produced by cells in TEVAs. CONCLUSIONS: These results provide direct evidence that the use of BMCs enables the establishment of TEVAs. These TEVAs are useful for cardiovascular surgery in humans and especially in children, who require biocompatible materials with growth potential, which might reduce the instance of complications caused by incompatible materials and lead to a reduced likelihood of further surgery.

Absorbable Implants↗

Long-term study of high-strength hydroxyapatite/poly(L-lactide) composite rods for the internal fixation of bone fractures: a 2-4-year follow-up study in rabbits.

Biodegradation of hydroxyapatite (HA)/poly(L-lactide)(PLLA) composite bone implant rods was studied with the use of two types of HA particles as reinforcing fillers: uncalcined HA (u-HA) or calcined HA (c-HA). Composite rods of u-HA/PLLA and c-HA/PLLA containing 30 or 40% (w/w) HA were implanted in the distal femur of 21 rabbits, and specimens were examined by light microscopy, scanning-electron microscopy (SEM), and transmission-electron microscopy (TEM) 2-4 years later. For u-HA/PLLA, trabecular bone bonding directly onto the rod was maintained for up to 2 years. By 3 years, surface collapse had begun, and the implants were shrinking. By 4 years, they had shrunk further, with complete bone encapsulation. The u-HA particles were small and needle shaped in the peripheries, and TEM confirmed their resorption. The cross-sectional area after 4 years decreased by 23.3+/-8.4%. The mean ratio of bony ingrowth to the initial cross-sectional area around the shrunken rods was 6.7+/-1.3 %. The viscosity molecular weight of PLLA reduced from 2 x 10(5) to less than 1 x 10(3). Thus, most of the PLLA had released from the rods. The c-HA/PLLA implants also showed good osteoconductivity, but shrinkage and infiltration of histiocytes were less. No osteolytic or osteoarthritic changes were found.

Absorbable Implants↗

In vivo efficacy of bone-marrow-coated polycaprolactone scaffolds for the reconstruction of orbital defects in the pig.

Alloplastic materials offer a number of advantages over bone autografts in the reconstruction of craniofacial defects. These include: lack of donor site morbidity, unlimited quantities of available material, and the possibility to conform exactly to the defect. An ideal bioresorbable material would degrade slowly, and have osteoconductive properties to allow replacement and remodeling by osseous tissue. This is seldom observed, the materials instead being replaced by fibrous tissue. Polycaprolactone (PCL), an FDA-approved bioresorbable polymer, has several properties that might make it suitable for reconstruction of craniofacial defects. The technique of fused deposition modeling (FDM) allows for the fabrication of highly reproducible bioresorbable 3D scaffolds. The nature of the fully interconnected pore network might enhance vascular ingrowth and osteoconductive properties. It was hypothesized that coating the scaffolds in bone marrow might enhance bone formation due to the osteoinductive nature of the bone-marrow mesenchymal cells. This study aimed to test these hypotheses in the pig model. Defects measuring 2 x 2 cm were surgically created in each orbit of eight Yorkshire pigs. The orbits were divided into three groups: Group 1 (n=4), no reconstruction (control); Group 2 (n=6), reconstruction with no coated PCL scaffolds; and Group 3 (n=6) reconstruction with bone-marrow-coated PCL scaffolds. The results were evaluated at 3 months by histological and histomorphometric analyses. The defects in Group 1 were covered with fibrous scar tissue. The shape of the reconstructed area was insufficient. The defects in Groups 2 and 3 were reconstructed correctly. In Group 2 the noncoated scaffolds showed 4.5% of new bone formation compared with 14.1% in Group 3, which is statistically significant (p<0.05). The entirely interconnected 3D polycaprolactone scaffold seems to be a promising material. It induces the bone ingrowth required for reconstructing craniofacial and orbital defects. Further long-term evaluations of these PCL scaffolds must be made in order to confirm these conclusions.

Absorbable Implants↗