Protein standardization III: Method optimization basic principles for quantitative determination of human serum proteins on automated instruments based on turbidimetry or nephelometry.

Abstract

Quantitative protein determinations in routine laboratories are today most often carried out using automated instruments. However, slight variations in the assay principle, in the programming of the instrument or in the reagents may lead to different results. This has led to the prerequisite of method optimization and standardization. The basic principles of turbidimetry and nephelometry are discussed. The different reading principles are illustrated and investigated. Various problems are identified and a suggestion is made for an integrated, fast and convenient test system for the determination of a number of different proteins on the same instrument. An optimized test system for turbidimetry and nephelometry should comprise high-quality antibodies, calibrators, controls, and buffers and a protocol with detailed parameter settings in order to program the instrument correctly. A good user program takes full advantage of the optimal reading principles for the different instruments. This implies--for all suitable instruments--sample preincubation followed by real sample blanking, which automatically corrects for initial turbidity in the sample. Likewise it is recommended to measure the reagent blank, which represents any turbidity caused by the antibody itself. By correcting all signals with these two blank values the best possible signal is obtained for the specific analyte. An optimized test system should preferably offer a wide measuring range combined with a wide security range, which for the user means few re-runs and maximum security against antigen excess. A non-linear calibration curve based on six standards is obtained using a suitable mathematical fitting model, which normally is part of the instrument software.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Blirup-Jensen. 2001. Protein standardization III: Method optimization basic principles for quantitative determination of human serum proteins on automated instruments based on turbidimetry or nephelometry.. https://doi.org/10.1515/cclm.2001.175

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Thermodynamic and kinetic analysis of the interaction between hepatitis B surface antibody and antigen on a gold electrode modified with cysteamine and colloidal gold via electrochemistry.

Hepatitis B surface antibody (HBsAb) was immobilized to the surface of a gold electrode modified with cysteamine and colloidal gold as matrices to detect hepatitis B surface antigen (HBsAg). Differential pulse voltammetry (DPV) method was used for the investigation of the specific interaction between the immobilized HBsAb and HBsAg in solution, which was followed as a change of peak current in DPV with time. With the modified gold electrode, the differences in affinity of HBsAb with HBsAg at the temperatures of 37 and 40 degrees C were easily distinguished and the kinetic rate constants (k(ass) and k(diss)) and kinetic affinity constant K were determined from the curves of current versus time. In addition, the thermodynamic constants, DeltaG, DeltaH and DeltaS, of the interaction at 37 degrees C were calculated, which were -56.65, -64.54 and -25.45 kJ mol(-1), respectively.

Antigen-Antibody Reactions↗

Impact of different inhibitor reactivities with commercial factor VIII concentrates on thrombin generation.

In order to describe the haemostatic role of a variation in inhibitor reactivity with different factor VIII (FVIII) concentrates, we have compared inhibitor titres against a panel of FVIII concentrates and correlated titre with the capacity to inhibit thrombin generation. Three plasma-derived concentrates were tested in vitro in mixing experiments with inhibitor plasmas from 11 patients with severe haemophilia A: Fanhdi, which contains von Willebrand factor (VWF) with a final ratio of approximately 1:1 (VWF IU per IU FVIII:C); Haemate-P with a ratio of 2.5:1 and Hemofil-M containing only trace amounts of VWF. In addition, the recombinant FVIII concentrate Kogenate Bayer containing no VWF was included. Inhibitor titres and the capacity to generate thrombin were measured. A statistically significant difference in measured titres was found with the highest titres recorded against Hemofil-M. The inhibitor titres needed to inhibit 50% maximum thrombin generation were the lowest for Kogenate Bayer and the highest and similar for Fanhdi and Haemate-P with intermediate titres needed for inhibition of Hemofil-M. In this study, the thrombin generation assay provides additional indications for the role of VWF in the treatment of patients with inhibitors. The VWF-containing concentrates Fanhdi and Haemate-P, added to FVIII-deficient plasma with the presence of inhibitor, generate more thrombin than do the purified concentrates Hemofil-M and Kogenate Bayer.

Antigen-Antibody Reactions↗