Developing a comprehensive mechanical support program.

Abstract

As cardiac surgery centers appreciate that ventricular assist devices (VAD) can dramatically impact patient survival as a bridge to transplant or recovery, and possibly permanent therapy, increasing numbers will desire to establish mechanical support programs. A number of vital elements must be put in place in order to operate a successful mechanical support program. Of utmost importance is the assembly of a dedicated team focused on comprehensive care of critically ill patients in need of circulatory support. An ongoing commitment from anesthesiologists, cardiologists, nephrologists, and other support staff is essential. Selection of complementary assist devices should be made to cover the spectrum of required support scenarios, both short- and long-term. Outpatient therapy has become increasingly important in mechanical cardiac assistance and establishment of an office where "LVAD coordinators" see outpatients facilitates this aspect of the program. Critically ill patients in need of cardiac assistance may benefit from specialized medical therapies such as: (1) intravenous arginine vasopressin for vasodilatory hypotension; (2) inhaled nitric oxide for right heart failure; (3) aprotinin to reduce hemorrhage; and (4) early enteral feeding in an effort to reduce infectious complications and improve rehabilitation following VAD implantation. A regional network with spoke hospitals centered around a hub hospital with long-term VAD and heart transplant programs can improve survival of patients with postcardiotomy cardiogenic shock via early transfer to the hub hospital. In this article, we describe the components of our mechanical support program that have allowed us to successfully support patients with heart failure in need of circulatory support.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D N Helman, M C Oz. Developing a comprehensive mechanical support program.. https://doi.org/10.1111/j.1540-8191.2001.tb00509.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Off-pump technique for Thoratec left ventricular assist device insertion.

We present a case of left ventricular assist device (Thoratec; Thoratec Laboratories Corp, Pleasanton, CA) insertion performed through a left thoracotomy without cardiopulmonary bypass in a patient with severe end-stage congestive heart failure with renal and respiratory dysfunction and a history of multiple cardiac operations.

Assisted Circulation↗

An experimental study of vascular dynamics by an acceleration plethysmogram using artificial circulation devices.

Plethysmogram has been widely known as a conventional non-invasive simple method to obtain information on peripheral circulatory kinetics. We made a quantitative assessment of the relationships between the various circulatory parameters, using the simple conventional measurement method of treating acceleration plethysmograms (the second derivatives of digital plethysmograms) as indicators of peripheral circulation kinetics. We designed a prototype model peripheral circulatory circuit, using an artificial heart, for the purpose of clarifying the relationship between physical factors and plethysmograms. In our models of the peripheral circulatory system, we made use of various types of matching silicon tubes, as well as canine carotid arteries, as substitutes for human arteries. We evaluated the mechanical characteristics, such as the pressure and volume characteristics of the silicon tubes and canine carotid arteries. Plethysmogram alterations were measured using a photoelectric digital plethysmogram. When we examined the acceleration plethysmogram b/a values, which indicate blood vessel extensibility and hardness, and the d/a values, which we were able to use as an index of peripheral circulatory kinetics, it was clear from out model testing that canine carotid arteries displayed b/a values that were closest to those found in the human fingertip; among artificial tubes, the closest was a tube with a diameter of 4 mm (0.18 mm in thickness). The b/a values of all types of tubes declined when the compliance of the arterial system was increased, and it was confirmed through model testing that b/a values are an indicator of blood vessel extensibility.

Assisted Circulation↗