Search PubMed⌕ Search

PubMed · 11769554

[Respiratory function tests--current and future perspective].

Abstract

The apparatus for the respiratory function test have recently made a great progress and become very easy to handle owing to the development of computer technology and medical ordering system. However, the respiratory function tests depend its result on the cooperation of patients. Thus, it is important for the medical technician to obtain the maximum efforts and cooperation of the patients in the testing. In the sense, the standardization of the testing should be done urgently regarding procedures, softwares, hardwares and maintenance of apparatus. In the future perspectives, we would like to emphasize following 3 points. First, more noninvasive and sophisticated testing methods and instruments should be developed, since the patients' age will become more and more old and vigorous active cooperation may not be possible for the assessment of respiratory function. The testing for the transplantation of lung should also be developed. Second, the development of screening test and its performance for the routine medical check for the local inhabitants have been important for the early detection, treatment, and follow up of respiratory diseases. Finally, the medical technician should be prepared so that the testing is available when it is needed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N Sano, Y Kamiyama, S Kato, T Himeno, S Yoshimatu, Y Magari, M Nakagawa, T Saikawa. 2001. [Respiratory function tests--current and future perspective].. https://searchpubmed.org/record/pubmed%3A11769554/respiratory-function-tests-current-and-future-perspective

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search PubMed by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

Expiratory flow limitation detected by forced oscillation and negative expiratory pressure.

The within-breath change in reactance (Delta(rs)) measured by forced oscillation technique (FOT) at 5 Hz reliably detects expiratory flow limitation in chronic obstructive pulmonary disease (COPD). The present study compared this approach to the standard negative expiratory pressure (NEP) method. In total, 21 COPD patients were studied by applying both techniques to the same breath and in 15 patients the measurements were repeated after bronchodilator. For each patient and condition five NEP tests were performed and independently scored by three operators unaware of the FOT results. In 180 tests, FOT classified 53.3% as flow limited. On average, the operators scored 27.6% of tests flow limited and 47.6% non-flow limited, but could not score 24.8%. The methods disagreed in 7.9% of cases; in 78% of these the NEP scores differed between operators. Bronchodilation reduced NEP and DeltaX(rs) scores, with only the latter achieving significance. Averaging the operators' NEP scores, a threshold between 24.6-30.8% of tidal volume being flow limited by NEP produced 94% agreement between methods. In conclusion, when negative expiratory pressure and forced oscillation technique were both available they showed good agreement. As forced oscillation technique is automatic and can measure multiple breaths over long periods, it is suitable for monitoring expiratory flow limitation continuously and identifying patients' breathing close to the onset of expiratory flow limitation, where intermittent sampling may be unrepresentative.

Forced Expiratory Flow Rates↗