Search PubMed⌕ Search

PubMed · 11765077

Flow-through sampling for electrophoresis-based microfluidic chips using hydrodynamic pumping.

Abstract

This work presents a novel electrophoretic microchip design which is capable of directly coupling with flow-through analyzers for uninterrupted sampling. In this device, a 3 mm wide sampling channel (SC) was etched on quartz substrate to create the sample inlet and outlet and the 75 microm wide electrophoretic channels were also fabricated on the same substrate. Pressure was used to drive the sample flow through the external tube into the SC and the flow was then split into outlet and electrophoretic channels. A gating voltage was applied to the electrophoretic channel to control the sample loading for subsequent separations and inhibit the sample leakage. The minimum gating voltage required to inhibit the sample leakage depended on the solution buffer and increased with the hydrodynamic flow-rate. A fluorescent dye mixture containing Rhodamine B and Cy3 was introduced into the sample stream at either a continuous or discrete mode via an on-line injection valve and then separated and detected on the microchip using laser-induced fluorescence. For both modes, the relative standard deviation of migration time and peak intensity for consecutive injections was determined to be below 0.6 and 8%, respectively. Because the SC was kept floating, the external sampling equipment requires no electric connection. Therefore, such an electrophoresis-based microchip can be directly coupled with any pressure-driven flow analyzers without hardware modifications. To our best knowledge, this is something currently impossible for reported electrophoretic microchip designs.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Y H Lin, G B Lee, C W Li, G R Huang, S H Chen. 2001-12-07. Flow-through sampling for electrophoresis-based microfluidic chips using hydrodynamic pumping.. https://doi.org/10.1016/s0021-9673(01)01326-7

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Biodegradability of imidazolium and pyridinium ionic liquids by an activated sludge microbial community.

Ionic liquids (ILs) are novel organic salts that have enormous potential for industrial use as green replacements for harmful volatile organic solvents. Varying the cationic components can alter the chemical and physical properties of ILs, including solubility, to suit a variety of industrial processes. However, to complement designer engineering, it is crucial to proactively characterize the biological impacts of new chemicals, in order to fully define them as environmentally friendly. Before introduction of ILs into the environment, we performed an analysis of the biodegradability of six ILs by activated sludge microorganisms collected from the South Bend, Indiana wastewater treatment plant. We examined biodegradability of 1-butyl, 1-hexyl and 1-octyl derivatives of 3-methyl-imidazolium and 3-methyl-pyridinium bromide compounds using the standard Organisation for Economic Cooperation and Development dissolved organic carbon Die-Away Test, changes in total dissolved nitrogen concentrations, and 1H-nuclear magnetic resonance analysis of initial and final chemical structures. Further, we examined microbial community profiles throughout the incubation period using denaturing gradient gel electrophoresis (DNA-PCR-DGGE). Our results suggest that hexyl and octyl substituted pyridinium-based ILs can be fully mineralized, but that imidazolium-based ILs are only partially mineralized. Butyl substituted ILs with either cation, were not biodegradable. Biodegradation rates also increase with longer alkyl chain length, which may be related to enhanced selection of a microbial community. Finally, DGGE analysis suggests that certain microorganisms are enriched by ILs used as a carbon source. Based on these results, we suggest that further IL design and synthesis include pyridinium cations and longer alkyl substitutions for rapid biodegradability.

Electrophoresis↗

Electrophoretic separation of human skeletal muscle myosin heavy chain isoforms: the importance of reducing agents.

An electrophoretic protocol previously used for the separation of rat myosin heavy chain (MHC) isoforms was slightly modified to improve the separation of human MHC isoforms in both large and minigel systems. The addition of reducing agents (beta-mercaptoethanol or dithiothreitol) to the top running buffer (TRB) radically improved separated MHC isoform resolution and the intensity of electrophoretic runs lasting longer than 5 h. In minigel systems, the MHC isoforms could be separated in as little as 5 h. The improved resolution of bands with the inclusion of reducing agents to the TRB facilitated the identification of clear boundaries for densitometric quantification of relative MHC isoform content, particularly for MHC IIa and MHC IIx. No significant effect of these reducing agents added to the TRB was observed for runs lasting only 100 min. Thus the inclusion of reducing agents in the TRB is essential for long electrophoretic runs, usually when separating large molecular mass proteins.

Electrophoresis↗