High-sensitivity coil array for head and neck imaging: technical note.

Abstract

The purpose of this study was to develop coils for MR imaging of the head and neck region, with the aim of improving sensitivity and coverage. A head and neck phased array coil was constructed and compared with volume and temporomandibular joint surface coils for sensitivity and coverage in phantom studies. An algorithm was implemented to correct for the nonuniformity in the surface coil reception profile. Its application to high-resolution T2-weighted imaging in healthy volunteers was investigated.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R G Henry, N J Fischbein, W P Dillon, D B Vigneron, S J Nelson. High-sensitivity coil array for head and neck imaging: technical note.. https://pubmed.ncbi.nlm.nih.gov/11733320/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

8.0-Tesla human MR system: temperature changes associated with radiofrequency-induced heating of a head phantom.

PURPOSE: To investigate if the heat induced in biological tissues by typical radio frequency (RF) energy associated with an 8.0-Tesla magnetic resonance (MR) system causes excessive temperature changes. MATERIALS AND METHODS: Fluoroptic thermometry was used to measure temperatures in multiple positions in a head phantom made of ground turkey breast. A series of experiments were conducted with measurements obtained at RF power levels ranging from a specific absorption rate (SAR) of up to 4.0 W/kg for 10 minutes. RESULTS: The highest temperature increases were up to 0.7 degrees C. An inhomogeneous heating pattern was observed. In general, the deep regions within the phantom registered higher temperature increases compared to the peripheral sites. CONCLUSION: The expectation of an inhomogeneous RF distribution in ultra high field systems (> 4 T) was confirmed. At a frequency of 340 MHz and in-tissue RF wave length of about 10 cm, the RF inhomogeneity was measured to create higher temperatures in deeper regions of a human head phantom compared to peripheral tissues. Our results agree with the computational electromagnetic calculations for such frequencies. Importantly, these experiments indicated that there were no regions of heating that exceeded the current FDA guidelines.

Head↗

Reconstruction after rotational motion.

Patient rotational motion during a scan causes the k-space sampling to be both irregular and undersampled. Conventional regridding requires an estimate of the sampling density at each measured point and is not strictly consistent with sampling theory. Here, a 2D problem is converted to a series of 1D regriddings by exact interpolation along the measured readouts. Each 1D regridding, expressed in matrix form, requires a matrix inversion to gain an exact solution. Undersampled regions make the matrix ill-conditioned but summing the matrix columns (without inversion) indicates the undersampled regions. The missing data could be reacquired, but in this study it is estimated using a Delaunay triangle-based linear interpolation on the original 2D data. The matrix conditioning is improved, leading to images with reduced artifacts compared to other regridding schemes. Furthermore, there is no requirement to estimate a density compensation function at each of the measured points.

Head↗

James Barrett Brown (1899-1971), head and neck surgeon of a half century ago.

This article summarizes the life and work of James Barrett Brown, MD (1899-1971), a plastic surgeon from St Louis, Mo, whose many contributions to the knowledge of surgery include his pioneering use of large split-thickness skin grafts to resurface defects. Along with a coauthor, he published an excellent book on radical neck dissection in 1954 (Neck Dissections, published by Charles C. Thomas, Springfield, Ill). Brown was a leading figure in the organization of high-quality plastic surgical care to injured soldiers in World War II. His training program in plastic surgery at Barnes Hospital in St Louis provided education to many leaders in the field. He received a number of honors for his many accomplishments.