Search PubMed⌕ Search

PubMed · 11700719

Field-effect flow control in a polydimethylsiloxane-based microfluidic system.

Abstract

The application of the field-effect for direct control of electroosmosis in a polydimethylsiloxane (PDMS)-based microfluidic system, constructed on a silicon wafer with a 2.0 microm electrically insulating layer of silicon dioxide, is demonstrated. This microfluidic system consists of a 2.0 cm open microchannel fabricated on a PDMS slab, which can reversibly adhere to the silicon wafer to form a hybrid microfluidic device. Aside from mechanically serving as a robust bottom substrate to seal the channel and support the microfluidic system, the silicon wafer is exploited to achieve field-effect flow control by grounding the semiconductive silicon medium. When an electric field is applied through the channel, a radial electric potential gradient is created across the silicon dioxide layer that allows for direct control of the zeta potential and the resulting electroosmotic flow (EOF). By configuring this microfluidic system with two power supplies at both ends of the microchannel, the applied electric potentials can be varied for manipulating the polarity and the magnitude of the radial electric potential gradient across the silicon dioxide layer. At the same time, the longitudinal potential gradient through the microchannel, which is used to induce EOF, is held constant. The results of EOF control in this hybrid microfluidic system are presented for phosphate buffer at pH 3 and pH 5. It is also demonstrated that EOF control can be performed at higher solution pH of 6 and 7.4 by modifying the silicon wafer surface with cetyltrimethylammonium bromide (CTAB) prior to assembly of the hybrid microfluidic system. Results of EOF control from this study are compared with those reported in the literature involving the use of other microfluidic devices under comparable solution conditions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J S Buch, P C Wang, D L DeVoe, C S Lee. 2001. Field-effect flow control in a polydimethylsiloxane-based microfluidic system.. https://doi.org/10.1002/1522-2683(200110)22%3A18%3C3902%3A%3Aaid-elps3902%3E3.0.co%3B2-k

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A novel pH-controlled transfer process of 5,10,15-tri(4-hydroxyphenyl)-20-(4-hexadecyloxyphenyl) porphyrin in CTAB micelles.

By analysis of the UV-visible and fluorescence spectra of 5,10,15-tri(4-hydroxyphenyl)-20-(4-hexadecyloxyphenyl)porphyrin (P) in different microenvironments of micelle and solvent solutions, a novel pH-controlled transfer process of P in CTAB micelle was reported. In neutral CTAB micelles, porphyrins may locate at the inner layers of micelles. With pH increases to 11.19, the porphyrin can be completely deprotonated and transfers to the outer surface of CTAB micelle. The investigation of kinetics of porphyrin complexing with Cu(II) indicates that the metallation rate of porphyrins in CTAB micelles could also be controlled by changing pH.

Cetrimonium↗

Investigation of the interaction between curcumin and nucleic acids in the presence of CTAB.

It is found that nucleic acid can enhance the resonance light scattering (RLS) enhancement effect of curcumin (CU) in the presence of cationic surfactant cetyltrimethylammonium bromide (CTAB). The investigation indicates that in BR (pH 4.3) buffer, both the positive CTAB and negative yeast RNA (yRNA) combine and form a positive large association, then which is bound on the two carbon atoms of the carbonyls of CU through hydrogen bond and hydrophobic force and form CU-CTAB-yRNA ternary complex, resulting in the RLS enhancement of this system. Based on it, a sensitive method for determination of nucleic acids at ngml(-1) is established.

Cetrimonium↗