Search PubMed⌕ Search

PubMed · 11691859

Temperature-modulated array high-performance liquid chromatography.

Abstract

Using novel monolithic poly(styrene-divinylbenzene) capillary columns with an internal diameter of 0.2 mm, we demonstrate for the first time the feasibility of constructing high-performance liquid chromatography arrays for the detection of mutations by heteroduplex analysis under partially denaturing conditions. In one embodiment, such an array can be used to analyze one sample simultaneously at different temperatures to maximize the detection of mutations in DNA fragments containing multiple discrete melting domains. Alternatively, one may inject different samples onto columns kept at the same effective temperature. Further improvements in throughput can be obtained by means of laser-induced fluorescence detection and the differential labeling of samples with up to four different fluorophores. Major advantages of monolithic capillary high-performance liquid chromatographic arrays over their capillary electrophoretic analogs are the chemical inertness of the poly(styrene-divinylbenzene) stationary phase, the physical robustness of the column bed due to its covalent linkage to the inner surface of the fused silica capillary, and the feasibility to modify the stationary phase thereby allowing the separation of compounds not only on the principle of size exclusion, but also adsorption, distribution, and ion exchange. Analyses times are on the order of a few minutes and turnaround time is extremely short as there is no need for the replenishment of the separation matrix between runs.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Premstaller, W Xiao, H Oberacher, M O'Keefe, D Stern, T Willis, C G Huber, P J Oefner. 2001. Temperature-modulated array high-performance liquid chromatography.. https://doi.org/10.1101/gr.200401

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Reversed-phase high-performance liquid chromatographic method for the determination of peptidoglycan monomers and structurally related peptides and adamantyltripeptides.

The reversed-phase HPLC method using UV detection was developed for the determination of (a) immunostimulating peptidoglycan monomers represented by the basic structure GlcNAc-MurNAc-L-Ala-D-isoGln-meso-DAP(omegaNH(2))-D-Ala-D-Ala (PGM) and two more lipophilic derivatives, Boc-Tyr-PGM and (Ada-1-yl)-CH(2)-CO-PGM, (b) two diastereomeric immunostimulating adamantyltripeptides L- and D-(adamant-2-yl)-Gly-L-Ala-D-isoGln and (c) peptides obtained by the enzyme hydrolyses of peptidoglycans and related peptides. The enzymes used, N-acetylmuramyl-L-alanine amidase and an L,D-aminopeptidase are present in mammalian sera and are involved in the metabolism of peptidoglycans and related peptides. Appropriate solvent systems were chosen with regard to structure and lipophilicity of each compound. As well, different gradient systems within the same solvent system had to be applied in order to achieve satisfactory separation and retention time. HPLC separation was developed with the aim to use this method for the study of the stability of the tested compounds, the purity during preparation and isolation and for following the enzyme hydrolyses.

Chromatography, High Pressure Liquid↗

Simultaneous determination of in total 17 opium alkaloids and opioids in blood and urine by fast liquid chromatography-diode-array detection-fluorescence detection, after solid-phase extraction.

A fast liquid chromatographic method with tandem diode array-fluorescence detection for the simultaneous determination of in total 17 opium alkaloids and opioids is presented. Blank blood and urine samples (1 ml) were spiked with different concentrations of a standard mixture, as well as with the internal standard, butorphanol (2000 ng/ml). After solid-phase extraction, based on weak cation exchange (Bond Elut CBA SPE columns), the extracts were examined by HPLC-DAD-FL. By using a "high-speed" phenyl column (53 x 7.0 mm I.D., particle size 3 microm) eluted with a gradient system (A: water-methanol (90:10, v/v), B: methanol, both containing 25 mM triethylammoniumformate (pH(A) = 4.5)) all compounds could be baseline separated within 12 min. The method was validated and its applicability was demonstrated by the analysis of real-time forensic cases.

Chromatography, High Pressure Liquid↗

Quantification and stability of everolimus (SDZ RAD) in human blood by high-performance liquid chromatography-electrospray tandem mass spectrometry.

We report here a validated method for the quantification of a new immunosuppressant drug, everolimus (SDZ RAD), using HPLC-tandem mass spectrometry. Whole blood samples (500 microl) were prepared by protein precipitation, followed by C(18) solid-phase extraction. Mass spectrometric detection was by selected reaction monitoring with an electrospray interface operating in positive ionization mode. The assay was linear from 0.5 to 100 microg/l (r(2) > 0.996, n = 9). The analytical recovery and inter-day imprecision, determined using whole blood quality control samples (n = 5) at 0.5, 1.2, 20.0, and 75.0 microg/l, was 100.3 - 105.4% and < or = 7.6%, respectively. The assay had a mean relative recovery of 94.8 +/- 3.8%. Extracted samples were stable for up to 24 h. Fortified everolimus blood samples were stable at -80 degrees C for at least 8 months and everolimus was found to be stable in blood when taken through at least three freeze-thaw cycles. The reported method provides accurate, precise and specific measurement of everolimus in blood over a wide analytical range and is currently supporting phase II and III clinical trials.

Chromatography, High Pressure Liquid↗