PubMed · 11679283

High-throughput PCR in silicon based microchamber array.

Abstract

Highly integrated hybridization assay and capillary electrophoresis have improved the throughput of DNA analysis. The shift to high throughput analysis requires a high speed DNA amplification system, and several rapid PCR systems have been developed. In these thermal cyclers, the temperature was controlled by effective methodology instead of a large heating/cooling block preventing rapid thermal cycling. In our research, high speed PCR was performed using a silicon-based microchamber array and three heat blocks. The highly integrated microchamber array was fabricated by semiconductor microfabrication techniques. The temperature of the PCR microchamber was controlled by alternating between three heat blocks of different temperature. In general, silicon has excellent thermal conductivity, and the heat capacity is small in the miniaturized sample volume. Hence, the heating/cooling rate was rapid, approximately 16 degrees C/s. The rapid PCR was therefore completed in 18 min for 40 cycles. The thermal cycle time was reduced to 1/10 of a commercial PCR instrument (Model 9600, PE Applied Biosystems-3 h).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Nagai, Y Murakami, K Yokoyama, E Tamiya. 2001. High-throughput PCR in silicon based microchamber array.. https://doi.org/10.1016/s0956-5663(01)00248-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Micromachined, silicon filament light source for spectrophotometric microsystems.

A miniature broadband light source is a critical element in a spectrophotometric microsystem. The design, fabrication, and characterization of a highly stable, miniature broadband light source that comprises filaments of single-crystal silicon are presented. Electrical current versus voltage and radiant emittance spectra under constant voltage bias are measured and related to filament dimensions. A maximum stable operating temperature for these filaments is estimated to be 1200 K. Resistance drift is demonstrated to be less than 0.5% over a 10-h period of continuous operation with visible incandescence. Emittance spectra of a multifilament array, measured at three different electrical biases, are presented and shown to compare well with theoretical blackbody radiation spectra. A continuous, total radiated power of 10.7 mW was achieved with a 1 mm x 1 mm filament array with peak emittance at lambda=2.7 micrometers.

Hot Temperature↗

Pressure- and temperature-induced unfolding and aggregation of recombinant human interferon-gamma: a Fourier transform infrared spectroscopy study.

The effect of hydrostatic pressure on the secondary structure of recombinant human interferon-gamma (rhIFN-gamma) and its biologically inactive truncated form rhIFN-Delta C15 has been studied using Fourier-transform IR (FTIR) spectroscopy. In situ observation of the pressure-induced changes using the diamond anvil cell shows that the alpha-helical structure is mainly transformed into disordered structure at high pressure. Increasing pressure also induces the formation of a gel. Addition of 0.5 M MgCl(2) significantly reduces the pressure stability. Releasing the pressure below 300 MPa results in the formation of intermolecular antiparallel beta-sheets, which is seldom observed. This suggests that the intermolecular beta-sheet of rhIFN-gamma is stabilized by electrostatic interactions that are disrupted at high pressure. For comparison we also studied the effect of temperature. Temperature-induced changes reflect extensive transformation of alpha-helical structure into intermolecular antiparallel beta-sheet, as is usually observed for most proteins.

Hot Temperature↗