Search PubMed⌕ Search

PubMed · 11679111

Single-pass continuous flow peritoneal dialysis using two catheters.

Abstract

With a renewed interest in continuous flow peritoneal dialysis (CFPD), our standard practice of implanting a second catheter in those patients facing access failure provided us the opportunity to perform acute studies on CFPD in these patients, since it temporarily provided us with two catheters. Four patients were studied, with a total of five studies performed. A standard protocol was followed utilizing 1.5% dextrose solution, a 2 L fill, an inflow rate of 200 ml/min with a proportionate outflow for a 4-hour session. A full drain was performed at the end of the study. Our results provided us with a mean effective peritoneal clearance for urea (KpeU) and creatinine (KpeCr) of 40 ml/min and 28 ml/min, respectively, and a mean ultrafiltration rate (Qf) of 13.4 ml/min. Our average mass transfer coefficient (MTC) for urea was 40 ml/min, consistent with kinetic modeling and historical data. The Kpe, MTC, and Qf achieved are significantly higher than other investigators, which could possibly be explained by those obtained by two separate catheters resulting in adequate mixing of the dialysate. These clinical results provide a solid foundation for the future development of this PD modality.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C Cruz, A Melendez, F A Gotch, T Folden, T L Crawford, J A Diaz-Buxo. Single-pass continuous flow peritoneal dialysis using two catheters.. https://doi.org/10.1046/j.1525-139x.2001.00098.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Immune heparin-induced thrombocytopenia resulting from preceding exposure to heparin catheter flushes.

Immune heparin-induced thrombocytopenia (HIT) is a life-threatening adverse effect of heparin. It can result from any type of heparin exposure and by any route of administration; however only a few cases are reported after exposures to small quantities of heparin from catheter flushes. The major clinical problem associated with HIT is thrombosis. Early detection and institution of alternative, non-heparin anticoagulation are important. We report a patient with HIT associated with use of therapeutic-dose unfractionated heparin in whom immune sensitization to heparin was triggered by two 500-unit exposure to UFH associated with intravascular catheter flushing for antineoplastic chemotherapy in a patient with colon adenocarcinoma.

Catheterization↗