Search PubMedSearch

PubMed · 1161438

Dark adaptation and short-wavelength backgrounds decrease perceived size.

Abstract

The effects of background luminance, contrast, and background wavelength on the perceived size of small line figures were studied at mesopic levels of light adaptation. Perceived size diminished at low levels of background luminance. The effect disappeared at high levels of luminance. Perceived size of luminous circles increased as a logarithmic function of background luminance when the background intensity did not exceed 25 td(1). The strength of the size effect decreased as a function of circle diameter from 0-125 to 2 deg of visual angle(2). Perceived size of small luminous circles, subtending less than 0-5 deg, also increased as a function of contrast at low values of contrast but at very high values of contrast there was a decrease in perceived size. Background luminance had the same effect on the perceived size of circles as on the perceived size of spatial cycles in gratings. Control experiments led to the conclusion that dark adaptation is the primary source of the size effects. The main evidence for this conclusion was obtained from a demonstration that the same background luminance produced either an increase or a decrease in perceived size, depending on the adaptational state of the eye. It was also found that a shift from cone vision to rod vision contributes to the effects, for a stimulus looked smaller on a short-wavelength background than on a long-wavelength background. The size effects can be predicted from the changes of receptive-field properties of single neurones under corresponding conditions of stimulation, if it is assumed that the perception of size is mediated by size-specific channels formed of single neurones. Stimulation that leads to an activation of small receptive fields appears to indicate to the brain the presence of small retinal images. If small receptive fields are experimentally made responsive to larger retinal images, an underestimation of size results.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

V Virsu, R Vuorinen. 1975. Dark adaptation and short-wavelength backgrounds decrease perceived size.. https://doi.org/10.1068/p040019

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Noise and the absolute thresholds of cone and rod vision.

Literature data on light detection by cone and rod vision at absolute threshold are analysed in order (1) to decide whether the threshold performance of dark-adapted cone vision can, like that of rod vision, be consistently explained as limited by noise from a "dark light"; (2) to obtain comparable estimates of the dark noise and dark light of (foveal) cones and (peripheral) rods. The dark noise was estimated by a maximum-likelihood procedure from frequency-of-seeing data and compared with the dark light derived from increment-threshold functions. In both cone and rod vision, the estimated dark noise coincides with Poisson fluctuations of the estimated dark light if 17% (best estimate) of lambda max-quanta incident at the cornea produce excitations. At that fraction of quanta exciting, dark lights are equivalent to 112 isomerisations per sec in each foveal cone and 0.011 isomerisations per sec in each rod. It is concluded that (1) the threshold performance of dark-adapted cone as well as rod vision can be consistently described as noise-limited, but not by postulating a multi-quantum coincidence requirement for single receptors; (2) the underlying intrinsic activity in both the cone and the rod system is light-like as regards correspondence between noise effect and background adaptation effect. One possibility is that this activity is largely composed of events identical to the single-photon response, originating in the visual pigment, in cones as well as in rods.

Dark Adaptation

Improving the diagnostic power of electroretinography by transient alteration of the ocular perfusion pressure.

In this report we present the results of a series of studies focusing on the effects of transient changes in the ocular perfusion pressure (OPP) on retinal function in normals as assessed by the flash electroretinogram (ERG). A transient increase or decrease in the OPP affected by body inversion and compression/suction ophthalmodynamometry (ODM), respectively, is shown to affect differentially the b-wave of scotopic and photopic ERG's. However, under dark-adapted conditions, the cone component of the red flash ERG b-wave exhibited a vulnerability to decreased OPP which approached that seen for the b-wave of the scotopic blue flash ERG b-wave. Similar test procedures used to investigate the functional response of the inner plexiform layer during altered OPP revealed component-specific changes in white flash scotopic oscillatory potentials (OP's). The results of these provocative tests of retinal function offer new insights into basic retinal physiology and encouraging prospects for practical clinical diagnostic procedures with enhanced sensitivity and specificity for subclinical retinal disorders.

Dark Adaptation