Search PubMed⌕ Search

PubMed · 11591918

[False hypopyons].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E Frau. 2001. [False hypopyons].. https://pubmed.ncbi.nlm.nih.gov/11591918/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Free radicals in phacoemulsification and aspiration procedures.

OBJECTIVES: To detect free radicals in phacoemulsification and aspiration procedures using electron-spin resonance and to observe the effect of ophthalmic viscosurgical devices (viscoelastic agents) on free radical intensity. METHODS: (1) A test tube containing BSS Plus (Alcon Laboratories, Inc, Fort Worth, Tex) with 1% of the spin-trapping agent, 5,5'-dimethyl-1-pyrroline N-oxide, without irrigation and aspiration, was exposed to ultrasound (100% for 20 seconds). A preparation of hyaluronate sodium (Healon [a cohesive agent that contains 1% hyaluronate sodium] (Pharmacia, Uppsala, Sweden) or Viscoat [a dispersive agent that contains 3% hyaluronate sodium and 4% chondroitin sulfate] (Alcon Laboratories, Inc)) was added to the solution to observe inhibitory effects. (2) To simulate a clinical procedure, an eye model with irrigation and aspiration of a combination of 1% 5,5'-dimethyl-1-pyrroline N-oxide and BSS Plus, 25 mL/min, as the irrigating solution was exposed to ultrasound (for 10, 20, or 30 seconds). Healon or Viscoat was injected into the anterior chamber. Free radicals were measured by an electron-spin resonance spectrometer. RESULTS: (1) A characteristic signal corresponding to hydroxyl radicals was detected. Similar inhibition by Healon and Viscoat was observed. (2) Two ophthalmic viscosurgical devices similarly suppressed the signal at 10 seconds. The inhibition by Healon ceased at 20 seconds, whereas Viscoat suppressed the signal throughout the time course. CONCLUSIONS: Phacoemulsification produces hydroxyl radicals in the anterior chamber even with irrigation and aspiration. The effect of ophthalmic viscosurgical devices on free radicals depends on the retention of the materials within the anterior chamber. CLINICAL RELEVANCE: There are complications associated with phacoemulsification.

Anterior Chamber↗

Transscleral optical coherence tomography--an experimental study in ex-vivo human eyes.

BACKGROUND AND OBJECTIVE: To evaluate the potentials of a 1310-nm optical coherence tomography (OCT) system to penetrate the highly backscattering sclera in enucleated human eyes and provide visualization of intraocular structures by transscleral imaging. STUDY DESIGN/MATERIALS AND METHODS: OCT-images were generated by an experimental prototype (Medical Laser Center, Lübeck, Germany) using a superluminescence diode with a wavelength of 1310 nm. OCT-images were taken from two enucleated human eyes using 100-200 axial scans with 60 Hz line scan frequency and compared to subsequent histologic sections. RESULTS: Transscleral OCT allowed penetration of the sclera and the anterior chamber angle could be completely identified. Some change within the anterior eye segment could be demonstrated with high accuracy. Additionally, limited demonstration of the ciliary body region was achieved. Due to limited signal intensity no detailed imaging of the pars plana and pars plicata region was possible. However, more posterior measurements allowed transscleral visualization of a retinal detachment. CONCLUSIONS: OCT using lightsources with a wavelength longer than that used in conventional OCT provides a promising imaging technique at high resolution allowing transscleral imaging of the anterior eye segment.

Anterior Chamber↗