Search PubMed⌕ Search

PubMed · 11547682

The technological edge.

Abstract

A MedLINK project has developed a novel coating for needles that provides maximum ultrasound signal contrast, thus improving their visibility and aiding their accurate placement durning interventional procedures.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Furness. 2001. The technological edge.. https://pubmed.ncbi.nlm.nih.gov/11547682/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Application of tissue-marking ink to prostate biopsy specimens.

BACKGROUND: When sextant prostate biopsy specimens are performed, noting the location from which cancer-containing cores were taken aids in treatment planning. However, many institutions include several cores in a single container, to cut costs. We have tried several methods of ink application and combining ink-labeled biopsy specimens into fewer containers with the goal of maintaining information regarding location while minimizing the expense. METHODS: Several approaches to the application of tissue-marking ink to biopsy cores, core-preparation methods, color combinations, and numbers of cores in each container were assessed. RESULTS: The ink adheres well to dry cores, but these cores often exhibit dehydration artifact. Placing the cores on a wet sponge avoids dehydration but causes ink spread. Excessive ink application occurs with eyedroppers and syringes but is avoided by touching each core with an ink-moistened cotton swab. Application of 1% acetic acid to the inked core promotes congealing of the ink onto the tissue. Yellow, orange, and red ink are more difficult to distinguish than blue, black, or green. Deciphering distinct cores when three or more cores are combined is difficult, especially if cores are fragmented. CONCLUSIONS: With our current protocol, all biopsy specimens are placed on separate moistened gauze sponges. Specimens from the right side of the prostate are marked by green ink, and those from the left side are marked by black ink with a cotton swab. After applying 1% acetic acid to each core, the left and right cores from each location are placed in a single container. This method curbs pathology expenses and maintains tumor location information.

Biopsy, Needle↗

Pancreas allograft biopsy: safety of percutaneous biopsy-results of a large experience.

BACKGROUND: Percutaneous pancreas allograft biopsy is the technique of choice for evaluation of pancreatic allograft rejection or dysfunction. The safety and success rate of the procedure with current surgical techniques is unclear. We report the complications and success rate in 426 consecutive percutaneous pancreas allograft biopsies performed at a single center. METHODS: One hundred eighty-three patients (50% simultaneous pancreas-kidney transplant, 42% pancreas after kidney transplant, 8% pancreas transplant alone) were biopsied. Biopsies were performed using an 18-gauge automated needle with ultrasound guidance. RESULTS: Thirty-seven patients had four or more biopsies (maximum, 11). Two hundred fifteen (50%) biopsies were in patients with bladder exocrine drainage, 211 (50%) in patients with enteric exocrine drainage. Of the latter, 33 (16%) were in patients with portal venous drainage. Eighty-eight percent of biopsy specimens were adequate for histologic diagnosis. There were 12 biopsy-related complications (2.8%), including eight episodes of bleeding (1.9%), five of which (1.2%) required surgical intervention and one possible extra-graft exocrine leak. Other complications included inadvertent liver (1), kidney (1), and small bowel (1) biopsy. CONCLUSIONS: Percutaneous pancreas allograft biopsy has a low rate of complication and a high success rate.

Biopsy, Needle↗

Transvenous transjugular renal core biopsy with a redesigned biopsy set including a blunt-tipped needle.

A novel 19-gauge, blunt-tipped, side cutting single throw, 70-cm long transjugular needle, specifically designed for transvenous kidney biopsy, was used in seven patients with high risk for bleeding. A mean of 4 device-passes (3-6) per patient resulted in a satisfactory specimen for pathological diagnosis. Immediate post-biopsy nonenhanced CT was performed to evaluate for bleeding at the biopsy site. All patients were observed for 2 hr after the procedure. No clinically significant immediate or late complication was noted.

Biopsy, Needle↗