Search PubMed⌕ Search

PubMed · 11527593

Automated embolus identification using a rule-based expert system.

Abstract

Transcranial Doppler ultrasound (US) can be used to detect microemboli in the cerebral circulation, but is still limited because it usually relies on "human experts" (HEs) to identify signals corresponding to embolic events. The purpose of this study was to develop an automatic system that could replace the HE and, thus, make the technique more widely applicable and, potentially, more reliable. An expert system, based around a digital signal-processing board, analysed Doppler signal patterns in both the time domain and frequency domain. The system was trained and tested on Doppler signals recorded during the dissection and recovery phases of carotid endarterectomy. It was tested with 74 separate 2.5-min recordings that contained at least 575 artefacts in addition to 253 s of diathermy interference. The results were compared with the results obtained by three HEs. Using a "gold-standard" that classified any event detected by the majority of HEs as an embolus, the automatic system displayed a sensitivity of 94.7% and a specificity of 95.1% for 1151 candidate events 7 dB or more above the clutter (signal-to-clutter ratio, SCR, > or = 7 dB), and 89.6% and 95.3%, respectively, for 2098 candidate events with SCR > or = 5 dB. The system had a very similar performance to individual HEs for SCR > or = 7dB, and was only marginally worse for SCR > or = 5 dB.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L Fan, D H Evans, A R Naylor. 2001. Automated embolus identification using a rule-based expert system.. https://doi.org/10.1016/s0301-5629(01)00414-8

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗